Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth44mm
Current limiting class3
Number of protected poles1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Over voltage category4
Frequency50 - 60Hz
Number of poles (total)1
Release characteristicD
Degree of protection (IP)IP20
Width in number of modular spacings1.5
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V3kA
Explosion-proofNo
Connectable conductor cross section solid-core1.5 - 50mm²
Concurrently switching neutral conductorNo
Rated current80A
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Flush-mounted installationNo
Rated insulation voltage Ui500V
Rated voltage230V
Pollution degree3
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 35mm²
Rated impulse withstand voltage Uimp6kV
Voltage typeAC
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9N18379

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

44mm

Current limiting class

3

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Over voltage category

4

Frequency

50 .. 60Hz

Number of poles (total)

1

Release characteristic

D

Degree of protection (IP)

IP20

Width in number of modular spacings

1.5

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

3kA

Explosion-proof

Connectable conductor cross section solid-core

1.5 .. 50mm²

Concurrently switching neutral conductor

Rated current

80A

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Flush-mounted installation

Rated insulation voltage Ui

500V

Rated voltage

230V

Pollution degree

3

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 35mm²

Rated impulse withstand voltage Uimp

6kV

Voltage type

AC

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.