Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class0
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Frequency- - -Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of protected poles1
Built-in depth44mm
Rated current32A
Rated voltage220V
Number of poles (total)1
Rated impulse withstand voltage Uimp6kV
Flush-mounted installationNo
Rated insulation voltage Ui500V
Concurrently switching neutral conductorNo
Release characteristicC
Voltage typeDC
Additional equipment possibleYes
Pollution degree3
Over voltage category4
Width in number of modular spacings2
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 35mm²
Ambient temperature during operating-25 - 70°C
Explosion-proofNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9N61515

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

0

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

- .. -Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of protected poles

1

Built-in depth

44mm

Rated current

32A

Rated voltage

220V

Number of poles (total)

1

Rated impulse withstand voltage Uimp

6kV

Flush-mounted installation

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

Release characteristic

C

Voltage type

DC

Additional equipment possible

Pollution degree

3

Over voltage category

4

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 35mm²

Ambient temperature during operating

-25 .. 70°C

Explosion-proof

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.