  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class0
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Frequency- - -Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Release characteristicC
Number of protected poles1
Concurrently switching neutral conductorNo
Built-in depth44mm
Additional equipment possibleYes
Rated current50A
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Degree of protection (IP)IP20
Width in number of modular spacings2
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section solid-core1 - 35mm²
Connectable conductor cross section multi-wired1 - 25mm²
Flush-mounted installationNo
Rated voltage220V
Number of poles (total)1
Over voltage category4
Pollution degree3
Explosion-proofNo
Voltage typeDC
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9N61518

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

0

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

- .. -Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

C

Number of protected poles

1

Concurrently switching neutral conductor

Built-in depth

44mm

Additional equipment possible

Rated current

50A

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section solid-core

1 .. 35mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation

Rated voltage

220V

Number of poles (total)

1

Over voltage category

4

Pollution degree

3

Explosion-proof

Voltage type

DC