Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class0
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Frequency- - -Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Release characteristicC
Number of poles (total)2
Number of protected poles1
Built-in depth44mm
Rated current1A
Rated voltage440V
Rated impulse withstand voltage Uimp6kV
Voltage typeDC
Rated insulation voltage Ui500V
Over voltage category4
Pollution degree3
Width in number of modular spacings4
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Ambient temperature during operating-25 - 70°C
Degree of protection (IP)IP20
Flush-mounted installationNo
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 16mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9N61521

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

0

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

- .. -Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

C

Number of poles (total)

2

Number of protected poles

1

Built-in depth

44mm

Rated current

1A

Rated voltage

440V

Rated impulse withstand voltage Uimp

6kV

Voltage type

DC

Rated insulation voltage Ui

500V

Over voltage category

4

Pollution degree

3

Width in number of modular spacings

4

Concurrently switching neutral conductor

Additional equipment possible

Ambient temperature during operating

-25 .. 70°C

Degree of protection (IP)

IP20

Flush-mounted installation

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 16mm²

Explosion-proof