Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency- - -Hz
Over voltage category4
Voltage typeDC
Current limiting class-
Release characteristicC
Rated current4A
Built-in depth44mm
Rated voltage440V
Rated insulation voltage Ui500V
Explosion-proofNo
Width in number of modular spacings2
Number of poles (total)2
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of protected poles2
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated impulse withstand voltage Uimp6kV
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Pollution degree3
Connectable conductor cross section multi-wired1 - 16mm²
Ambient temperature during operating-25 - 70°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9N61524 | Prekidac Minijaturni C60H-DC 2P 4A C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency

- .. -Hz

Over voltage category

4

Voltage type

DC

Current limiting class

-

Release characteristic

C

Rated current

4A

Built-in depth

44mm

Rated voltage

440V

Rated insulation voltage Ui

500V

Explosion-proof

Width in number of modular spacings

2

Number of poles (total)

2

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of protected poles

2

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated impulse withstand voltage Uimp

6kV

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Pollution degree

3

Connectable conductor cross section multi-wired

1 .. 16mm²

Ambient temperature during operating

-25 .. 70°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.