Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class0
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Built-in depth44mm
Number of protected poles2
Release characteristicC
Rated current5A
Number of poles (total)2
Rated voltage440V
Flush-mounted installationNo
Rated insulation voltage Ui500V
Over voltage category4
Voltage typeDC
Rated impulse withstand voltage Uimp6kV
Concurrently switching neutral conductorNo
Pollution degree3
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 70°C
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 16mm²
Explosion-proofNo
Width in number of modular spacings2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9N61525

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

0

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Built-in depth

44mm

Number of protected poles

2

Release characteristic

C

Rated current

5A

Number of poles (total)

2

Rated voltage

440V

Flush-mounted installation

Rated insulation voltage Ui

500V

Over voltage category

4

Voltage type

DC

Rated impulse withstand voltage Uimp

6kV

Concurrently switching neutral conductor

Pollution degree

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 70°C

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 16mm²

Explosion-proof

Width in number of modular spacings

2

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.