Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Explosion-proofNo
Degree of protection (IP)IP40
Rated insulation voltage Ui1000V
Number of protected poles2
Built-in depth44mm
Rated current10A
Rated voltage800V
Width in number of modular spacings4
Frequency50 - 50Hz
Pollution degree2
Voltage typeDC
Release characteristicB
Over voltage category4
Connectable conductor cross section solid-core1 - 25mm²
Current limiting class-
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Flush-mounted installationNo
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Connectable conductor cross section multi-wired1 - 16mm²
Ambient temperature during operating-25 - 70°C
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9N61650 | Prekidac za PV C60PV-DC 2P 10A 800VDC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Explosion-proof

Degree of protection (IP)

IP40

Rated insulation voltage Ui

1000V

Number of protected poles

2

Built-in depth

44mm

Rated current

10A

Rated voltage

800V

Width in number of modular spacings

4

Frequency

50 .. 50Hz

Pollution degree

2

Voltage type

DC

Release characteristic

B

Over voltage category

4

Connectable conductor cross section solid-core

1 .. 25mm²

Current limiting class

-

Concurrently switching neutral conductor

Additional equipment possible

Flush-mounted installation

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Connectable conductor cross section multi-wired

1 .. 16mm²

Ambient temperature during operating

-25 .. 70°C

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.