Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Release characteristicB
Number of poles (total)2
Number of protected poles2
Built-in depth44mm
Rated current16A
Rated voltage800V
Rated insulation voltage Ui1000V
Rated impulse withstand voltage Uimp6kV
Voltage typeDC
Pollution degree2
Frequency50 - 50Hz
Current limiting class0
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Width in number of modular spacings4
Degree of protection (IP)Other
Ambient temperature during operating-25 - 70°C
Over voltage category4
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 16mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9N61651

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

B

Number of poles (total)

2

Number of protected poles

2

Built-in depth

44mm

Rated current

16A

Rated voltage

800V

Rated insulation voltage Ui

1000V

Rated impulse withstand voltage Uimp

6kV

Voltage type

DC

Pollution degree

2

Frequency

50 .. 50Hz

Current limiting class

0

Flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Width in number of modular spacings

4

Degree of protection (IP)

Other

Ambient temperature during operating

-25 .. 70°C

Over voltage category

4

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 16mm²

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.