Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V1.5kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V1.5kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth44mm
Rated current13A
Rated voltage800V
Number of protected poles2
Rated insulation voltage Ui1000V
Number of poles (total)2
Release characteristicB
Rated impulse withstand voltage Uimp6kV
Frequency50 - 50Hz
Voltage typeDC
Concurrently switching neutral conductorYes
Over voltage category4
Flush-mounted installationNo
Pollution degree2
Ambient temperature during operating-25 - 70°C
Width in number of modular spacings4
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 16mm²
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9N61658

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

1.5kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

1.5kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

44mm

Rated current

13A

Rated voltage

800V

Number of protected poles

2

Rated insulation voltage Ui

1000V

Number of poles (total)

2

Release characteristic

B

Rated impulse withstand voltage Uimp

6kV

Frequency

50 .. 50Hz

Voltage type

DC

Concurrently switching neutral conductor

Over voltage category

4

Flush-mounted installation

Pollution degree

2

Ambient temperature during operating

-25 .. 70°C

Width in number of modular spacings

4

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 16mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.