  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V1.5kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V1.5kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated current15A
Rated insulation voltage Ui1000V
Built-in depth44mm
Concurrently switching neutral conductorYes
Number of poles (total)2
Over voltage category4
Width in number of modular spacings4
Explosion-proofNo
Rated impulse withstand voltage Uimp6kV
Frequency50 - 50Hz
Rated voltage800V
Ambient temperature during operating-25 - 70°C
Pollution degree2
Flush-mounted installationNo
Number of protected poles2
Release characteristicB
Additional equipment possibleYes
Degree of protection (IP)IP20
Voltage typeDC
Connectable conductor cross section multi-wired1 - 16mm²
Connectable conductor cross section solid-core1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9N61659

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

1.5kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

1.5kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated current

15A

Rated insulation voltage Ui

1000V

Built-in depth

44mm

Concurrently switching neutral conductor

Number of poles (total)

2

Over voltage category

4

Width in number of modular spacings

4

Explosion-proof

Rated impulse withstand voltage Uimp

6kV

Frequency

50 .. 50Hz

Rated voltage

800V

Ambient temperature during operating

-25 .. 70°C

Pollution degree

2

Flush-mounted installation

Number of protected poles

2

Release characteristic

B

Additional equipment possible

Degree of protection (IP)

IP20

Voltage type

DC

Connectable conductor cross section multi-wired

1 .. 16mm²

Connectable conductor cross section solid-core

1 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.