Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency50 - 50Hz
Rated current15A
Voltage typeDC
Release characteristicB
Rated voltage800V
Width in number of modular spacings4
Rated insulation voltage Ui1000V
Degree of protection (IP)IP20
Number of protected poles2
Connectable conductor cross section solid-core1 - 25mm²
Built-in depth44mm
Explosion-proofNo
Current limiting class-
Concurrently switching neutral conductorYes
Over voltage category4
Pollution degree2
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V1.5kA
Rated impulse withstand voltage Uimp6kV
Flush-mounted installationNo
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section multi-wired1 - 16mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V1.5kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

A9N61659 | Prekidac za PV C60PV-DC 2P 15A 800VDC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency

50 .. 50Hz

Rated current

15A

Voltage type

DC

Release characteristic

B

Rated voltage

800V

Width in number of modular spacings

4

Rated insulation voltage Ui

1000V

Degree of protection (IP)

IP20

Number of protected poles

2

Connectable conductor cross section solid-core

1 .. 25mm²

Built-in depth

44mm

Explosion-proof

Current limiting class

-

Concurrently switching neutral conductor

Over voltage category

4

Pollution degree

2

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

1.5kA

Rated impulse withstand voltage Uimp

6kV

Flush-mounted installation

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section multi-wired

1 .. 16mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

1.5kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.