Aleta.hr

Details

  • Low-voltage industrial components
  • Pressure switch
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP65
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact1
Rated operation power at AC-3, 400 V0kW
Type of electric connectionScrew connection
Rated operation current Ie at AC-3, 400 V0A
Number of normally closed contacts as main contact0
Rated operation current Ie at AC-1, 400 V0A
Number of normally open contacts as main contact0
Explosion-proofNo
Rated voltage Ue at AC 50 Hz24 - 500V
Rated voltage Ue at AC 60 Hz0 - 0V
Rated voltage Ue at DC24 - 600V
Adjustable current range0 - 0A
Max. operation pressure17000hPa
With manual on/off switchNo
Bursting pressure7bar
Suitable as 2-point controllerYes
Electronic versionNo
Suitable as limiterYes
Suitable as guardYes
With hand operationNo
Medium temperature-73 - 125°C
Pressure-switching differential0.7bar
End setting70 - 7600hPa
Switch off pressure0.07 - 7.6bar
Initial setting370 - 6200hPa
Engaging pressure0.07 - 7.6bar
Max. test pressure1bar
Initial value measuring range pressure370000Pa
Switching capacity at AC-3, 240 V0kA
End value measuring range pressure620000Pa
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ACW5M119012

Main Product Image

Details

  • Low-voltage industrial components
  • Pressure switch
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP65

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

1

Rated operation power at AC-3, 400 V

0kW

Type of electric connection

Screw connection

Rated operation current Ie at AC-3, 400 V

0A

Number of normally closed contacts as main contact

0

Rated operation current Ie at AC-1, 400 V

0A

Number of normally open contacts as main contact

0

Explosion-proof

Rated voltage Ue at AC 50 Hz

24 .. 500V

Rated voltage Ue at AC 60 Hz

0 .. 0V

Rated voltage Ue at DC

24 .. 600V

Adjustable current range

0 .. 0A

Max. operation pressure

17000hPa

With manual on/off switch

Bursting pressure

7bar

Suitable as 2-point controller

Electronic version

Suitable as limiter

Suitable as guard

With hand operation

Medium temperature

-73 .. 125°C

Pressure-switching differential

0.7bar

End setting

70 .. 7600hPa

Switch off pressure

0.07 .. 7.6bar

Initial setting

370 .. 6200hPa

Engaging pressure

0.07 .. 7.6bar

Max. test pressure

1bar

Initial value measuring range pressure

370000Pa

Switching capacity at AC-3, 240 V

0kA

End value measuring range pressure

620000Pa

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.