Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

With control elementYes
Number of analogue inputs1
Number of digital inputs4
Width72mm
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Depth102.2mm
Number of analogue outputs1
Height143mm
Number of digital outputs1
Number of HW-interfaces RS-2320
Supporting protocol for CANNo
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Supporting protocol for KNXNo
Supporting protocol for ASINo
Number of HW-interfaces RS-4220
Supporting protocol for INTERBUSNo
With optical interfaceNo
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Number of HW-interfaces other8
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces serial TTY0
Supporting protocol for TCP/IPNo
Number of HW-interfaces RS-4851
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Supporting protocol for other bus systemsNo
4-quadrant operation possibleNo
Degree of protection (IP)IP20
Mains voltage100 - 120V
With PC connectionYes
Supporting protocol for SERCOSNo
Number of phases output3
Max. output frequency400Hz
Integrated breaking resistanceNo
Number of phases input1
Type of converterU converter
Application in domestic- and commercial area permittedYes
Max. output at linear load at rated output voltage0.18kW
Number of interfaces PROFINET0
Application in industrial area permittedYes
Max. output at quadratic load at rated output voltage0.18kW
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
Max. output voltage230V
Nominal output current I2N1.4A
Supporting protocol for EtherNet/IPNo
Relative symmetric net frequency tolerance5%
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV12H018F1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

With control element

Number of analogue inputs

1

Number of digital inputs

4

Width

72mm

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for LON

Depth

102.2mm

Number of analogue outputs

1

Height

143mm

Number of digital outputs

1

Number of HW-interfaces RS-232

0

Supporting protocol for CAN

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Supporting protocol for KNX

Supporting protocol for ASI

Number of HW-interfaces RS-422

0

Supporting protocol for INTERBUS

With optical interface

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Number of HW-interfaces other

8

Supporting protocol for SUCONET

Supporting protocol for PROFIBUS

Number of HW-interfaces serial TTY

0

Supporting protocol for TCP/IP

Number of HW-interfaces RS-485

1

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Supporting protocol for other bus systems

4-quadrant operation possible

Degree of protection (IP)

IP20

Mains voltage

100 .. 120V

With PC connection

Supporting protocol for SERCOS

Number of phases output

3

Max. output frequency

400Hz

Integrated breaking resistance

Number of phases input

1

Type of converter

U converter

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

0.18kW

Number of interfaces PROFINET

0

Application in industrial area permitted

Max. output at quadratic load at rated output voltage

0.18kW

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Max. output voltage

230V

Nominal output current I2N

1.4A

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

5%

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.