Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital outputs1
Number of analogue outputs1
Number of analogue inputs1
Number of HW-interfaces serial TTY0
Height142mm
Number of digital inputs4
Number of HW-interfaces parallel0
Number of HW-interfaces other8
Number of HW-interfaces USB0
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet0
With optical interfaceNo
Supporting protocol for LONNo
Depth156.2mm
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
With control elementYes
Width105mm
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for KNXNo
Number of interfaces PROFINET0
Number of phases output3
4-quadrant operation possibleNo
Supporting protocol for other bus systemsNo
Supporting protocol for PROFIBUSNo
Type of converterU converter
Degree of protection (IP)IP20
Supporting protocol for ModbusYes
Integrated breaking resistanceNo
Supporting protocol for DeviceNetNo
Number of phases input1
Mains frequency50/60 Hz
Supporting protocol for INTERBUSNo
Supporting protocol for INTERBUS-SafetyNo
Application in industrial area permittedYes
With PC connectionYes
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Mains voltage100 - 120V
Supporting protocol for Data-HighwayNo
Max. output frequency400Hz
Max. output at linear load at rated output voltage0.75kW
Application in domestic- and commercial area permittedYes
Supporting protocol for EtherNet/IPNo
Max. output at quadratic load at rated output voltage0.75kW
Relative symmetric net frequency tolerance5%
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
Nominal output current I2N4.2A
Max. output voltage230V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV12H075F1 | Pretvarac Frek. ATV12 0,55 KW Hladnjak

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital outputs

1

Number of analogue outputs

1

Number of analogue inputs

1

Number of HW-interfaces serial TTY

0

Height

142mm

Number of digital inputs

4

Number of HW-interfaces parallel

0

Number of HW-interfaces other

8

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

With optical interface

Supporting protocol for LON

Depth

156.2mm

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

With control element

Width

105mm

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for KNX

Number of interfaces PROFINET

0

Number of phases output

3

4-quadrant operation possible

Supporting protocol for other bus systems

Supporting protocol for PROFIBUS

Type of converter

U converter

Degree of protection (IP)

IP20

Supporting protocol for Modbus

Integrated breaking resistance

Supporting protocol for DeviceNet

Number of phases input

1

Mains frequency

50/60 Hz

Supporting protocol for INTERBUS

Supporting protocol for INTERBUS-Safety

Application in industrial area permitted

With PC connection

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Mains voltage

100 .. 120V

Supporting protocol for Data-Highway

Max. output frequency

400Hz

Max. output at linear load at rated output voltage

0.75kW

Application in domestic- and commercial area permitted

Supporting protocol for EtherNet/IP

Max. output at quadratic load at rated output voltage

0.75kW

Relative symmetric net frequency tolerance

5%

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Nominal output current I2N

4.2A

Max. output voltage

230V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.