Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width140mm
Height184mm
Depth141.2mm
Number of HW-interfaces RS-4851
Number of analogue inputs1
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Number of analogue outputs1
Number of HW-interfaces other8
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
Number of HW-interfaces RS-4220
Number of digital inputs4
Supporting protocol for TCP/IPNo
With optical interfaceNo
Supporting protocol for ASINo
Number of digital outputs1
With control elementYes
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Supporting protocol for DeviceNetNo
Number of HW-interfaces USB0
Degree of protection (IP)IP20
Mains voltage200 - 240V
With PC connectionYes
Type of converterU converter
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Mains frequency50/60 Hz
Number of interfaces PROFINET0
Max. output frequency400Hz
Application in domestic- and commercial area permittedYes
Max. output at linear load at rated output voltage4kW
Number of phases output3
4-quadrant operation possibleNo
Max. output at quadratic load at rated output voltage4kW
Number of phases input3
Supporting protocol for other bus systemsNo
Application in industrial area permittedYes
Integrated breaking resistanceNo
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Relative symmetric net frequency tolerance5%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Max. output voltage230V
Supporting protocol for PROFIsafeNo
Nominal output current I2N16.7A
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV12HU40M3 | Pretvarac Frek. ATV12 4 KW Hladnjak

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

140mm

Height

184mm

Depth

141.2mm

Number of HW-interfaces RS-485

1

Number of analogue inputs

1

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Number of analogue outputs

1

Number of HW-interfaces other

8

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Number of digital inputs

4

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for ASI

Number of digital outputs

1

With control element

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for DeviceNet

Number of HW-interfaces USB

0

Degree of protection (IP)

IP20

Mains voltage

200 .. 240V

With PC connection

Type of converter

U converter

Supporting protocol for INTERBUS-Safety

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

Max. output frequency

400Hz

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

4kW

Number of phases output

3

4-quadrant operation possible

Max. output at quadratic load at rated output voltage

4kW

Number of phases input

3

Supporting protocol for other bus systems

Application in industrial area permitted

Integrated breaking resistance

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Relative symmetric net frequency tolerance

5%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Max. output voltage

230V

Supporting protocol for PROFIsafe

Nominal output current I2N

16.7A

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.