Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height143mm
Number of digital outputs1
Width72mm
Depth102.2mm
With control elementYes
Number of digital inputs4
Number of analogue outputs1
Number of analogue inputs1
Supporting protocol for LONNo
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Supporting protocol for PROFIBUSNo
With optical interfaceNo
Number of HW-interfaces other8
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for KNXNo
Supporting protocol for ASINo
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
With PC connectionYes
Supporting protocol for DeviceNetNo
Degree of protection (IP)IP20
Supporting protocol for INTERBUS-SafetyNo
Mains voltage200 - 240V
Supporting protocol for INTERBUSNo
Number of interfaces PROFINET0
Type of converterU converter
Number of phases output3
Integrated breaking resistanceNo
Number of phases input1
Mains frequency50/60 Hz
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Relative symmetric net frequency tolerance5%
Max. output frequency400Hz
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage0.55kW
Supporting protocol for AS-Interface Safety at WorkNo
4-quadrant operation possibleNo
Max. output at quadratic load at rated output voltage0.55kW
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for BACnetNo
Nominal output current I2N3.5A
Max. output voltage230V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV12P055M2 | Pretvarac Frek. ATV12 0,55 KW Ploca

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height

143mm

Number of digital outputs

1

Width

72mm

Depth

102.2mm

With control element

Number of digital inputs

4

Number of analogue outputs

1

Number of analogue inputs

1

Supporting protocol for LON

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Supporting protocol for PROFIBUS

With optical interface

Number of HW-interfaces other

8

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

Supporting protocol for other bus systems

Supporting protocol for SUCONET

With PC connection

Supporting protocol for DeviceNet

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS-Safety

Mains voltage

200 .. 240V

Supporting protocol for INTERBUS

Number of interfaces PROFINET

0

Type of converter

U converter

Number of phases output

3

Integrated breaking resistance

Number of phases input

1

Mains frequency

50/60 Hz

Application in industrial area permitted

Application in domestic- and commercial area permitted

Relative symmetric net frequency tolerance

5%

Max. output frequency

400Hz

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

0.55kW

Supporting protocol for AS-Interface Safety at Work

4-quadrant operation possible

Max. output at quadratic load at rated output voltage

0.55kW

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for BACnet

Nominal output current I2N

3.5A

Max. output voltage

230V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.