Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of analogue inputs1
Number of HW-interfaces industrial Ethernet0
Height143mm
With control elementYes
Width72mm
Number of digital outputs1
Number of HW-interfaces RS-4220
Depth102.2mm
Number of digital inputs4
Supporting protocol for LONNo
Number of analogue outputs1
Number of HW-interfaces RS-2320
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUSNo
Mains voltage200 - 240V
Supporting protocol for other bus systemsNo
Supporting protocol for INTERBUS-SafetyNo
Number of HW-interfaces other8
Number of HW-interfaces USB0
With optical interfaceNo
Supporting protocol for KNXNo
Mains frequency50/60 Hz
Supporting protocol for Data-HighwayNo
4-quadrant operation possibleNo
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Supporting protocol for ModbusYes
Supporting protocol for ASINo
With PC connectionYes
Supporting protocol for CANNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Number of interfaces PROFINET0
Supporting protocol for PROFIBUSNo
Number of phases input3
Max. output voltage230V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Application in domestic- and commercial area permittedYes
Supporting protocol for PROFINET IONo
Supporting protocol for BACnetNo
Nominal output current I2N4.2A
Integrated breaking resistanceNo
Supporting protocol for Foundation FieldbusNo
Relative symmetric net frequency tolerance5%
Max. output at linear load at rated output voltage0.75kW
Supporting protocol for EtherNet/IPNo
Max. output frequency400Hz
Application in industrial area permittedYes
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET CBANo
Max. output at quadratic load at rated output voltage0.75kW
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Number of phases output3
Type of converterU converter
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV12P075M3 | Pretvarac Frek. ATV12 0,75 KW Ploca

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of analogue inputs

1

Number of HW-interfaces industrial Ethernet

0

Height

143mm

With control element

Width

72mm

Number of digital outputs

1

Number of HW-interfaces RS-422

0

Depth

102.2mm

Number of digital inputs

4

Supporting protocol for LON

Number of analogue outputs

1

Number of HW-interfaces RS-232

0

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Mains voltage

200 .. 240V

Supporting protocol for other bus systems

Supporting protocol for INTERBUS-Safety

Number of HW-interfaces other

8

Number of HW-interfaces USB

0

With optical interface

Supporting protocol for KNX

Mains frequency

50/60 Hz

Supporting protocol for Data-Highway

4-quadrant operation possible

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Supporting protocol for Modbus

Supporting protocol for ASI

With PC connection

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Number of interfaces PROFINET

0

Supporting protocol for PROFIBUS

Number of phases input

3

Max. output voltage

230V

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Application in domestic- and commercial area permitted

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Nominal output current I2N

4.2A

Integrated breaking resistance

Supporting protocol for Foundation Fieldbus

Relative symmetric net frequency tolerance

5%

Max. output at linear load at rated output voltage

0.75kW

Supporting protocol for EtherNet/IP

Max. output frequency

400Hz

Application in industrial area permitted

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET CBA

Max. output at quadratic load at rated output voltage

0.75kW

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Number of phases output

3

Type of converter

U converter

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.