  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mains voltage200 - 240V
Mains frequency50/60 Hz
Max. output voltage230V
Max. output frequency400Hz
Number of phases output3
Number of phases input3
Max. output at linear load at rated output voltage4kW
Nominal output current I2N16.7A
Max. output at quadratic load at rated output voltage4kW
Relative symmetric net frequency tolerance5%
Number of analogue inputs1
Number of digital outputs1
Number of analogue outputs1
Relative symmetric net voltage tolerance10%
Number of digital inputs4
Application in industrial area permittedYes
With control elementYes
Application in domestic- and commercial area permittedYes
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusYes
Supporting protocol for CANNo
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for ASINo
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for PROFINET IONo
Supporting protocol for LONNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for SERCOSNo
Number of HW-interfaces industrial Ethernet0
Supporting protocol for BACnetNo
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Number of interfaces PROFINET0
Number of HW-interfaces other8
Supporting protocol for other bus systemsNo
Number of HW-interfaces serial TTY0
Supporting protocol for INTERBUS-SafetyNo
With optical interfaceNo
With PC connectionYes
Integrated breaking resistanceNo
4-quadrant operation possibleNo
Type of converterU converter
Degree of protection (IP)IP20
Height184mm
Depth100.2mm
Width140mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV12PU40M3

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mains voltage

200 .. 240V

Mains frequency

50/60 Hz

Max. output voltage

230V

Max. output frequency

400Hz

Number of phases output

3

Number of phases input

3

Max. output at linear load at rated output voltage

4kW

Nominal output current I2N

16.7A

Max. output at quadratic load at rated output voltage

4kW

Relative symmetric net frequency tolerance

5%

Number of analogue inputs

1

Number of digital outputs

1

Number of analogue outputs

1

Relative symmetric net voltage tolerance

10%

Number of digital inputs

4

Application in industrial area permitted

With control element

Application in domestic- and commercial area permitted

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for ASI

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for PROFINET IO

Supporting protocol for LON

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for SERCOS

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for BACnet

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Number of interfaces PROFINET

0

Number of HW-interfaces other

8

Supporting protocol for other bus systems

Number of HW-interfaces serial TTY

0

Supporting protocol for INTERBUS-Safety

With optical interface

With PC connection

Integrated breaking resistance

4-quadrant operation possible

Type of converter

U converter

Degree of protection (IP)

IP20

Height

184mm

Depth

100.2mm

Width

140mm

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.