Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width240mm
Height420mm
Number of HW-interfaces industrial Ethernet0
With control elementYes
Number of digital outputs0
Supporting protocol for LONYes
Number of analogue outputs1
Number of analogue inputs2
Number of digital inputs3
Depth214mm
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4851
Number of HW-interfaces parallel0
With optical interfaceNo
Number of HW-interfaces other0
Number of HW-interfaces RS-4220
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for TCP/IPNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for CANNo
Supporting protocol for SUCONETNo
With PC connectionYes
Supporting protocol for other bus systemsYes
Mains voltage380 - 480V
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUSNo
Degree of protection (IP)IP21
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for DeviceNetNo
Mains frequency50/60 Hz
Type of converterU converter
Relative symmetric net voltage tolerance10%
Number of interfaces PROFINET0
Application in industrial area permittedYes
4-quadrant operation possibleNo
Relative symmetric net frequency tolerance5%
Integrated breaking resistanceNo
Max. output at quadratic load at rated output voltage30kW
Max. output at linear load at rated output voltage30kW
Application in domestic- and commercial area permittedYes
Number of phases input3
Number of phases output3
Supporting protocol for AS-Interface Safety at WorkNo
Max. output frequency200Hz
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for BACnetNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Max. output voltage480V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Nominal output current I2N58.5A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV212HD30N4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

240mm

Height

420mm

Number of HW-interfaces industrial Ethernet

0

With control element

Number of digital outputs

0

Supporting protocol for LON

Number of analogue outputs

1

Number of analogue inputs

2

Number of digital inputs

3

Depth

214mm

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces parallel

0

With optical interface

Number of HW-interfaces other

0

Number of HW-interfaces RS-422

0

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS-Safety

Supporting protocol for TCP/IP

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for SUCONET

With PC connection

Supporting protocol for other bus systems

Mains voltage

380 .. 480V

Supporting protocol for SERCOS

Supporting protocol for INTERBUS

Degree of protection (IP)

IP21

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for DeviceNet

Mains frequency

50/60 Hz

Type of converter

U converter

Relative symmetric net voltage tolerance

10%

Number of interfaces PROFINET

0

Application in industrial area permitted

4-quadrant operation possible

Relative symmetric net frequency tolerance

5%

Integrated breaking resistance

Max. output at quadratic load at rated output voltage

30kW

Max. output at linear load at rated output voltage

30kW

Application in domestic- and commercial area permitted

Number of phases input

3

Number of phases output

3

Supporting protocol for AS-Interface Safety at Work

Max. output frequency

200Hz

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for BACnet

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Max. output voltage

480V

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Nominal output current I2N

58.5A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.