Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth244mm
Height550mm
With control elementYes
Number of digital inputs3
Width240mm
Number of digital outputs0
Supporting protocol for LONYes
Number of analogue outputs1
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Supporting protocol for CANNo
Number of HW-interfaces serial TTY0
Number of analogue inputs2
Number of HW-interfaces RS-4851
With optical interfaceNo
Supporting protocol for ASINo
Number of HW-interfaces other0
Number of HW-interfaces USB0
Supporting protocol for PROFIBUSNo
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUSNo
With PC connectionYes
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Degree of protection (IP)IP21
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Supporting protocol for other bus systemsYes
Number of phases output3
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
4-quadrant operation possibleNo
Number of phases input3
Number of interfaces PROFINET0
Type of converterU converter
Mains voltage380 - 480V
Mains frequency50/60 Hz
Supporting protocol for AS-Interface Safety at WorkNo
Integrated breaking resistanceNo
Max. output at quadratic load at rated output voltage45kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Application in domestic- and commercial area permittedYes
Supporting protocol for Foundation FieldbusNo
Max. output frequency200Hz
Supporting protocol for EtherNet/IPNo
Relative symmetric net frequency tolerance5%
Relative symmetric net voltage tolerance10%
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Application in industrial area permittedYes
Max. output at linear load at rated output voltage45kW
Max. output voltage480V
Supporting protocol for BACnetNo
Nominal output current I2N94A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV212HD45N4 | Pretvarac FREK.45KW 480V 3P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth

244mm

Height

550mm

With control element

Number of digital inputs

3

Width

240mm

Number of digital outputs

0

Supporting protocol for LON

Number of analogue outputs

1

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Supporting protocol for CAN

Number of HW-interfaces serial TTY

0

Number of analogue inputs

2

Number of HW-interfaces RS-485

1

With optical interface

Supporting protocol for ASI

Number of HW-interfaces other

0

Number of HW-interfaces USB

0

Supporting protocol for PROFIBUS

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

With PC connection

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Degree of protection (IP)

IP21

Supporting protocol for SUCONET

Supporting protocol for KNX

Supporting protocol for other bus systems

Number of phases output

3

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

4-quadrant operation possible

Number of phases input

3

Number of interfaces PROFINET

0

Type of converter

U converter

Mains voltage

380 .. 480V

Mains frequency

50/60 Hz

Supporting protocol for AS-Interface Safety at Work

Integrated breaking resistance

Max. output at quadratic load at rated output voltage

45kW

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Application in domestic- and commercial area permitted

Supporting protocol for Foundation Fieldbus

Max. output frequency

200Hz

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

5%

Relative symmetric net voltage tolerance

10%

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Application in industrial area permitted

Max. output at linear load at rated output voltage

45kW

Max. output voltage

480V

Supporting protocol for BACnet

Nominal output current I2N

94A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.