Technical specifications

Number of phases output3
Number of phases input3
Mains voltage380 - 480V
Max. output voltage480V
Mains frequency50/60 Hz
Nominal output current I2N116A
Max. output frequency200Hz
Max. output at quadratic load at rated output voltage55kW
Max. output at linear load at rated output voltage55kW
Relative symmetric net frequency tolerance5%
With optical interfaceNo
Relative symmetric net voltage tolerance10%
Number of analogue outputs1
Number of analogue inputs2
With PC connectionYes
Integrated breaking resistanceNo
4-quadrant operation possibleNo
Type of converterU converter
Height630mm
Depth290mm
Degree of protection (IP)IP21
Width320mm
Number of digital inputs3
Number of digital outputs0
Application in industrial area permittedYes
With control elementYes
Application in domestic- and commercial area permittedYes
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for LONYes
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for BACnetNo
Number of HW-interfaces RS-4220
Number of interfaces PROFINET0
Supporting protocol for AS-Interface Safety at WorkNo
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsYes
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces USB0
Number of HW-interfaces other0
Number of HW-interfaces parallel0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV212HD55N4

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of phases output

3

Number of phases input

3

Mains voltage

380 .. 480V

Max. output voltage

480V

Mains frequency

50/60 Hz

Nominal output current I2N

116A

Max. output frequency

200Hz

Max. output at quadratic load at rated output voltage

55kW

Max. output at linear load at rated output voltage

55kW

Relative symmetric net frequency tolerance

5%

With optical interface

Relative symmetric net voltage tolerance

10%

Number of analogue outputs

1

Number of analogue inputs

2

With PC connection

Integrated breaking resistance

4-quadrant operation possible

Type of converter

U converter

Height

630mm

Depth

290mm

Degree of protection (IP)

IP21

Width

320mm

Number of digital inputs

3

Number of digital outputs

0

Application in industrial area permitted

With control element

Application in domestic- and commercial area permitted

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Supporting protocol for INTERBUS-Safety

Supporting protocol for BACnet

Number of HW-interfaces RS-422

0

Number of interfaces PROFINET

0

Supporting protocol for AS-Interface Safety at Work

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Number of HW-interfaces other

0

Number of HW-interfaces parallel

0

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.