Technical specifications

Number of HW-interfaces RS-4220
Number of HW-interfaces other0
Supporting protocol for LONYes
Supporting protocol for PROFIBUSNo
With optical interfaceNo
Width142mm
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2320
Height184mm
Number of analogue inputs2
Number of digital outputs0
Depth150mm
Number of digital inputs3
Number of HW-interfaces parallel0
Number of HW-interfaces industrial Ethernet0
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Number of HW-interfaces serial TTY0
Number of analogue outputs1
With control elementYes
Number of HW-interfaces USB0
Mains frequency50/60 Hz
Supporting protocol for DeviceNetNo
Number of phases input3
Supporting protocol for other bus systemsYes
4-quadrant operation possibleNo
Type of converterU converter
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Supporting protocol for INTERBUS-SafetyNo
Application in domestic- and commercial area permittedYes
Supporting protocol for KNXNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP21
Number of interfaces PROFINET0
Application in industrial area permittedYes
Supporting protocol for SUCONETNo
Integrated breaking resistanceNo
Number of phases output3
Max. output frequency200Hz
With PC connectionYes
Mains voltage380 - 480V
Supporting protocol for ModbusYes
Max. output at linear load at rated output voltage5.5kW
Max. output at quadratic load at rated output voltage5.5kW
Supporting protocol for SafetyBUS pNo
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance5%
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for BACnetNo
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Max. output voltage480V
Supporting protocol for PROFINET CBANo
Nominal output current I2N12A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV212HU55N4 | Pretvarac Frek. 5,5 KW 480 V 3P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

0

Supporting protocol for LON

Supporting protocol for PROFIBUS

With optical interface

Width

142mm

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-232

0

Height

184mm

Number of analogue inputs

2

Number of digital outputs

0

Depth

150mm

Number of digital inputs

3

Number of HW-interfaces parallel

0

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for TCP/IP

Supporting protocol for ASI

Number of HW-interfaces serial TTY

0

Number of analogue outputs

1

With control element

Number of HW-interfaces USB

0

Mains frequency

50/60 Hz

Supporting protocol for DeviceNet

Number of phases input

3

Supporting protocol for other bus systems

4-quadrant operation possible

Type of converter

U converter

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for CAN

Supporting protocol for INTERBUS-Safety

Application in domestic- and commercial area permitted

Supporting protocol for KNX

Supporting protocol for SERCOS

Degree of protection (IP)

IP21

Number of interfaces PROFINET

0

Application in industrial area permitted

Supporting protocol for SUCONET

Integrated breaking resistance

Number of phases output

3

Max. output frequency

200Hz

With PC connection

Mains voltage

380 .. 480V

Supporting protocol for Modbus

Max. output at linear load at rated output voltage

5.5kW

Max. output at quadratic load at rated output voltage

5.5kW

Supporting protocol for SafetyBUS p

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

5%

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for BACnet

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Max. output voltage

480V

Supporting protocol for PROFINET CBA

Nominal output current I2N

12A