Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width215mm
Number of digital inputs3
Number of HW-interfaces industrial Ethernet0
With control elementYes
Number of HW-interfaces RS-2320
Number of analogue inputs2
Supporting protocol for LONYes
Depth192mm
Number of HW-interfaces RS-4220
Number of digital outputs0
Height297mm
Number of analogue outputs1
Number of HW-interfaces RS-4851
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Supporting protocol for ModbusYes
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for TCP/IPNo
With optical interfaceNo
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Number of HW-interfaces other0
Supporting protocol for KNXNo
With PC connectionYes
Supporting protocol for other bus systemsYes
Number of interfaces PROFINET0
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP55
Supporting protocol for SERCOSNo
Mains voltage380 - 480V
Supporting protocol for DeviceNetNo
4-quadrant operation possibleNo
Mains frequency50/60 Hz
Supporting protocol for SUCONETNo
Integrated breaking resistanceNo
Type of converterU converter
Number of phases output3
Number of phases input3
Application in domestic- and commercial area permittedYes
Supporting protocol for EtherNet/IPNo
Relative symmetric net voltage tolerance10%
Max. output frequency200Hz
Application in industrial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at quadratic load at rated output voltage0.75kW
Relative symmetric net frequency tolerance5%
Max. output at linear load at rated output voltage0.75kW
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Nominal output current I2N2.2A
Supporting protocol for BACnetNo
Max. output voltage480V
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV212W075N4C | Pretvarac Frek 0,75KW 480V 3P EMC B IP54

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

215mm

Number of digital inputs

3

Number of HW-interfaces industrial Ethernet

0

With control element

Number of HW-interfaces RS-232

0

Number of analogue inputs

2

Supporting protocol for LON

Depth

192mm

Number of HW-interfaces RS-422

0

Number of digital outputs

0

Height

297mm

Number of analogue outputs

1

Number of HW-interfaces RS-485

1

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for Data-Highway

Supporting protocol for CAN

Number of HW-interfaces other

0

Supporting protocol for KNX

With PC connection

Supporting protocol for other bus systems

Number of interfaces PROFINET

0

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP55

Supporting protocol for SERCOS

Mains voltage

380 .. 480V

Supporting protocol for DeviceNet

4-quadrant operation possible

Mains frequency

50/60 Hz

Supporting protocol for SUCONET

Integrated breaking resistance

Type of converter

U converter

Number of phases output

3

Number of phases input

3

Application in domestic- and commercial area permitted

Supporting protocol for EtherNet/IP

Relative symmetric net voltage tolerance

10%

Max. output frequency

200Hz

Application in industrial area permitted

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Max. output at quadratic load at rated output voltage

0.75kW

Relative symmetric net frequency tolerance

5%

Max. output at linear load at rated output voltage

0.75kW

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Nominal output current I2N

2.2A

Supporting protocol for BACnet

Max. output voltage

480V