Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital outputs0
Number of analogue outputs1
Width284mm
Number of digital inputs3
Height720mm
Number of analogue inputs2
With control elementYes
Depth315mm
Number of HW-interfaces RS-4851
Number of HW-interfaces parallel0
With optical interfaceNo
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP55
Supporting protocol for ModbusYes
Supporting protocol for SERCOSNo
Number of HW-interfaces other0
Supporting protocol for TCP/IPNo
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Supporting protocol for CANNo
With PC connectionYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Number of HW-interfaces RS-4220
Number of HW-interfaces serial TTY0
Supporting protocol for LONYes
Supporting protocol for KNXNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces USB0
Supporting protocol for INTERBUSNo
Number of phases input3
Mains frequency50/60 Hz
Number of phases output3
Type of converterU converter
Integrated breaking resistanceNo
Mains voltage380 - 480V
4-quadrant operation possibleNo
Number of interfaces PROFINET0
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IONo
Max. output voltage480V
Application in industrial area permittedYes
Supporting protocol for PROFINET CBANo
Max. output frequency200Hz
Relative symmetric net frequency tolerance5%
Supporting protocol for EtherNet/IPNo
Max. output at quadratic load at rated output voltage22kW
Max. output at linear load at rated output voltage22kW
Application in domestic- and commercial area permittedYes
Nominal output current I2N43.5A
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV212WD22N4 | Pretvarac Frek. 22KW 480V 3P EMC a IP54

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital outputs

0

Number of analogue outputs

1

Width

284mm

Number of digital inputs

3

Height

720mm

Number of analogue inputs

2

With control element

Depth

315mm

Number of HW-interfaces RS-485

1

Number of HW-interfaces parallel

0

With optical interface

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP55

Supporting protocol for Modbus

Supporting protocol for SERCOS

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for CAN

With PC connection

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Number of HW-interfaces RS-422

0

Number of HW-interfaces serial TTY

0

Supporting protocol for LON

Supporting protocol for KNX

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Number of HW-interfaces USB

0

Supporting protocol for INTERBUS

Number of phases input

3

Mains frequency

50/60 Hz

Number of phases output

3

Type of converter

U converter

Integrated breaking resistance

Mains voltage

380 .. 480V

4-quadrant operation possible

Number of interfaces PROFINET

0

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Max. output voltage

480V

Application in industrial area permitted

Supporting protocol for PROFINET CBA

Max. output frequency

200Hz

Relative symmetric net frequency tolerance

5%

Supporting protocol for EtherNet/IP

Max. output at quadratic load at rated output voltage

22kW

Max. output at linear load at rated output voltage

22kW

Application in domestic- and commercial area permitted

Nominal output current I2N

43.5A

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.