Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width284mm
With control elementYes
Number of analogue outputs1
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet0
Number of digital outputs0
Number of HW-interfaces RS-2320
Number of analogue inputs2
Supporting protocol for LONYes
Number of digital inputs3
Number of HW-interfaces USB0
Height720mm
Supporting protocol for ASINo
Number of HW-interfaces serial TTY0
With optical interfaceNo
Depth315mm
Number of HW-interfaces parallel0
Supporting protocol for PROFIBUSNo
Number of HW-interfaces RS-4220
Number of HW-interfaces other0
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for other bus systemsYes
Supporting protocol for Data-HighwayNo
Degree of protection (IP)IP55
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusYes
Supporting protocol for CANNo
Number of phases input3
Supporting protocol for SERCOSNo
Type of converterU converter
Number of interfaces PROFINET0
Mains voltage380 - 480V
Mains frequency50/60 Hz
Number of phases output3
Application in industrial area permittedYes
Integrated breaking resistanceNo
Supporting protocol for INTERBUS-SafetyNo
4-quadrant operation possibleNo
Max. output at linear load at rated output voltage30kW
With PC connectionYes
Application in domestic- and commercial area permittedYes
Max. output frequency200Hz
Max. output at quadratic load at rated output voltage30kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
Relative symmetric net frequency tolerance5%
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Nominal output current I2N58.5A
Max. output voltage480V
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV212WD30N4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

284mm

With control element

Number of analogue outputs

1

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Number of digital outputs

0

Number of HW-interfaces RS-232

0

Number of analogue inputs

2

Supporting protocol for LON

Number of digital inputs

3

Number of HW-interfaces USB

0

Height

720mm

Supporting protocol for ASI

Number of HW-interfaces serial TTY

0

With optical interface

Depth

315mm

Number of HW-interfaces parallel

0

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Degree of protection (IP)

IP55

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for CAN

Number of phases input

3

Supporting protocol for SERCOS

Type of converter

U converter

Number of interfaces PROFINET

0

Mains voltage

380 .. 480V

Mains frequency

50/60 Hz

Number of phases output

3

Application in industrial area permitted

Integrated breaking resistance

Supporting protocol for INTERBUS-Safety

4-quadrant operation possible

Max. output at linear load at rated output voltage

30kW

With PC connection

Application in domestic- and commercial area permitted

Max. output frequency

200Hz

Max. output at quadratic load at rated output voltage

30kW

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Relative symmetric net frequency tolerance

5%

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Nominal output current I2N

58.5A

Max. output voltage

480V

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.