Number of phases input3
Mains voltage380 - 480V
Max. output frequency200Hz
Nominal output current I2N160A
Max. output at quadratic load at rated output voltage75kW
Max. output at linear load at rated output voltage75kW
Max. output voltage480V
Relative symmetric net frequency tolerance5%
Number of analogue outputs1
Relative symmetric net voltage tolerance10%
Number of analogue inputs2
With control elementYes
Number of digital inputs3
Number of digital outputs0
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Application in industrial area permittedYes
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Supporting protocol for TCP/IPNo
Supporting protocol for LONYes
Mains frequency50/60 Hz
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFINET IONo
Supporting protocol for SUCONETNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNetNo
Supporting protocol for SERCOSNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetNo
Supporting protocol for PROFINET CBANo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Number of phases output3
Application in domestic- and commercial area permittedYes
With optical interfaceNo
4-quadrant operation possibleNo
Type of converterU converter
Integrated breaking resistanceNo
With PC connectionYes
Degree of protection (IP)IP55
Height1000mm
Width362mm
Depth364mm
Number of interfaces PROFINET0
Number of HW-interfaces USB0
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Supporting protocol for other bus systemsYes
Number of HW-interfaces RS-4851
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Number of HW-interfaces industrial Ethernet0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV212WD75N4

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of phases input

3

Mains voltage

380 .. 480V

Max. output frequency

200Hz

Nominal output current I2N

160A

Max. output at quadratic load at rated output voltage

75kW

Max. output at linear load at rated output voltage

75kW

Max. output voltage

480V

Relative symmetric net frequency tolerance

5%

Number of analogue outputs

1

Relative symmetric net voltage tolerance

10%

Number of analogue inputs

2

With control element

Number of digital inputs

3

Number of digital outputs

0

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Application in industrial area permitted

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for TCP/IP

Supporting protocol for LON

Mains frequency

50/60 Hz

Supporting protocol for Data-Highway

Supporting protocol for PROFINET IO

Supporting protocol for SUCONET

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for SafetyBUS p

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for ASI

Supporting protocol for KNX

Number of phases output

3

Application in domestic- and commercial area permitted

With optical interface

4-quadrant operation possible

Type of converter

U converter

Integrated breaking resistance

With PC connection

Degree of protection (IP)

IP55

Height

1000mm

Width

362mm

Depth

364mm

Number of interfaces PROFINET

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Supporting protocol for other bus systems

Number of HW-interfaces RS-485

1

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

Number of HW-interfaces industrial Ethernet

0

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.