Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth192mm
With control elementYes
Height297mm
Width215mm
Number of digital inputs3
Number of digital outputs0
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Number of analogue inputs2
Supporting protocol for LONYes
Supporting protocol for PROFIBUSNo
Number of HW-interfaces RS-4220
Number of HW-interfaces other0
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Number of HW-interfaces parallel0
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for CANNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4851
With optical interfaceNo
Supporting protocol for ModbusYes
Number of analogue outputs1
Number of HW-interfaces USB0
Degree of protection (IP)IP55
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetNo
Mains voltage380 - 480V
With PC connectionYes
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Max. output at linear load at rated output voltage1.5kW
Number of phases output3
Number of phases input3
4-quadrant operation possibleNo
Application in industrial area permittedYes
Type of converterU converter
Supporting protocol for AS-Interface Safety at WorkNo
Mains frequency50/60 Hz
Relative symmetric net voltage tolerance10%
Max. output frequency200Hz
Number of interfaces PROFINET0
Supporting protocol for EtherNet/IPNo
Max. output at quadratic load at rated output voltage1.5kW
Relative symmetric net frequency tolerance5%
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N3.7A
Max. output voltage480V
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV212WU15N4 | Pretvarac Frek. 1,5KW 480V 3P EMC a IP54

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth

192mm

With control element

Height

297mm

Width

215mm

Number of digital inputs

3

Number of digital outputs

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Number of analogue inputs

2

Supporting protocol for LON

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

Supporting protocol for ASI

Number of HW-interfaces parallel

0

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for CAN

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-485

1

With optical interface

Supporting protocol for Modbus

Number of analogue outputs

1

Number of HW-interfaces USB

0

Degree of protection (IP)

IP55

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Mains voltage

380 .. 480V

With PC connection

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Max. output at linear load at rated output voltage

1.5kW

Number of phases output

3

Number of phases input

3

4-quadrant operation possible

Application in industrial area permitted

Type of converter

U converter

Supporting protocol for AS-Interface Safety at Work

Mains frequency

50/60 Hz

Relative symmetric net voltage tolerance

10%

Max. output frequency

200Hz

Number of interfaces PROFINET

0

Supporting protocol for EtherNet/IP

Max. output at quadratic load at rated output voltage

1.5kW

Relative symmetric net frequency tolerance

5%

Application in domestic- and commercial area permitted

Integrated breaking resistance

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Nominal output current I2N

3.7A

Max. output voltage

480V

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.