Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width215mm
Height297mm
Number of digital inputs3
Depth192mm
Number of digital outputs0
Number of HW-interfaces other0
Number of analogue inputs2
Supporting protocol for LONYes
Number of HW-interfaces RS-2320
With control elementYes
Supporting protocol for CANNo
Number of HW-interfaces parallel0
Number of analogue outputs1
Supporting protocol for KNXNo
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet0
Supporting protocol for TCP/IPNo
With optical interfaceNo
Supporting protocol for ASINo
Number of HW-interfaces USB0
Supporting protocol for PROFIBUSNo
Number of HW-interfaces serial TTY0
Supporting protocol for INTERBUSNo
Number of HW-interfaces RS-4220
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
4-quadrant operation possibleNo
Type of converterU converter
With PC connectionYes
Supporting protocol for other bus systemsYes
Mains frequency50/60 Hz
Supporting protocol for Foundation FieldbusNo
Integrated breaking resistanceNo
Max. output at linear load at rated output voltage2.2kW
Supporting protocol for INTERBUS-SafetyNo
Relative symmetric net voltage tolerance10%
Number of interfaces PROFINET0
Mains voltage380 - 480V
Application in industrial area permittedYes
Supporting protocol for AS-Interface Safety at WorkNo
Max. output frequency200Hz
Supporting protocol for SERCOSNo
Max. output at quadratic load at rated output voltage2.2kW
Number of phases output3
Degree of protection (IP)IP55
Number of phases input3
Application in domestic- and commercial area permittedYes
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance5%
Max. output voltage480V
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for BACnetNo
Nominal output current I2N5.1A
Supporting protocol for SafetyBUS pNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV212WU22N4 | Pretvarac Frek. 2,2KW 480V 3P EMC a IP54

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

215mm

Height

297mm

Number of digital inputs

3

Depth

192mm

Number of digital outputs

0

Number of HW-interfaces other

0

Number of analogue inputs

2

Supporting protocol for LON

Number of HW-interfaces RS-232

0

With control element

Supporting protocol for CAN

Number of HW-interfaces parallel

0

Number of analogue outputs

1

Supporting protocol for KNX

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for ASI

Number of HW-interfaces USB

0

Supporting protocol for PROFIBUS

Number of HW-interfaces serial TTY

0

Supporting protocol for INTERBUS

Number of HW-interfaces RS-422

0

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

4-quadrant operation possible

Type of converter

U converter

With PC connection

Supporting protocol for other bus systems

Mains frequency

50/60 Hz

Supporting protocol for Foundation Fieldbus

Integrated breaking resistance

Max. output at linear load at rated output voltage

2.2kW

Supporting protocol for INTERBUS-Safety

Relative symmetric net voltage tolerance

10%

Number of interfaces PROFINET

0

Mains voltage

380 .. 480V

Application in industrial area permitted

Supporting protocol for AS-Interface Safety at Work

Max. output frequency

200Hz

Supporting protocol for SERCOS

Max. output at quadratic load at rated output voltage

2.2kW

Number of phases output

3

Degree of protection (IP)

IP55

Number of phases input

3

Application in domestic- and commercial area permitted

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

5%

Max. output voltage

480V

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for BACnet

Nominal output current I2N

5.1A

Supporting protocol for SafetyBUS p

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.