Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth208mm
Number of digital inputs3
Width230mm
Supporting protocol for LONYes
Number of analogue inputs2
Number of analogue outputs1
Height340mm
With control elementYes
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4851
Number of digital outputs0
Number of HW-interfaces other0
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
With optical interfaceNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Mains voltage380 - 480V
With PC connectionYes
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for CANNo
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP55
Supporting protocol for ASINo
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Type of converterU converter
4-quadrant operation possibleNo
Number of interfaces PROFINET0
Number of HW-interfaces USB0
Max. output frequency200Hz
Max. output at quadratic load at rated output voltage4kW
Supporting protocol for AS-Interface Safety at WorkNo
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Supporting protocol for BACnetNo
Number of phases output3
Number of phases input3
Nominal output current I2N9.1A
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET IONo
Max. output voltage480V
Supporting protocol for SafetyBUS pNo
Relative symmetric net frequency tolerance5%
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage4kW
Supporting protocol for Foundation FieldbusNo
Integrated breaking resistanceNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV212WU40N4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth

208mm

Number of digital inputs

3

Width

230mm

Supporting protocol for LON

Number of analogue inputs

2

Number of analogue outputs

1

Height

340mm

With control element

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-485

1

Number of digital outputs

0

Number of HW-interfaces other

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

With optical interface

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Mains voltage

380 .. 480V

With PC connection

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for CAN

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP55

Supporting protocol for ASI

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Type of converter

U converter

4-quadrant operation possible

Number of interfaces PROFINET

0

Number of HW-interfaces USB

0

Max. output frequency

200Hz

Max. output at quadratic load at rated output voltage

4kW

Supporting protocol for AS-Interface Safety at Work

Application in domestic- and commercial area permitted

Application in industrial area permitted

Supporting protocol for BACnet

Number of phases output

3

Number of phases input

3

Nominal output current I2N

9.1A

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Max. output voltage

480V

Supporting protocol for SafetyBUS p

Relative symmetric net frequency tolerance

5%

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

4kW

Supporting protocol for Foundation Fieldbus

Integrated breaking resistance