Technical specifications

Number of digital inputs3
Height340mm
Supporting protocol for LONYes
Number of analogue outputs1
Depth208mm
With control elementYes
Width230mm
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Number of analogue inputs2
Number of HW-interfaces RS-4220
Number of digital outputs0
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Supporting protocol for ModbusYes
Mains frequency50/60 Hz
Number of HW-interfaces parallel0
Supporting protocol for PROFIBUSNo
Mains voltage380 - 480V
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Supporting protocol for ASINo
Supporting protocol for other bus systemsYes
Number of HW-interfaces other0
4-quadrant operation possibleNo
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for KNXNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNetNo
With PC connectionYes
Supporting protocol for INTERBUSNo
Number of interfaces PROFINET0
With optical interfaceNo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4851
Degree of protection (IP)IP55
Type of converterU converter
Number of phases output3
Number of phases input3
Supporting protocol for DeviceNet SafetyNo
Application in industrial area permittedYes
Max. output at quadratic load at rated output voltage5.5kW
Supporting protocol for EtherNet/IPNo
Relative symmetric net frequency tolerance5%
Max. output frequency200Hz
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Max. output at linear load at rated output voltage5.5kW
Supporting protocol for AS-Interface Safety at WorkNo
Integrated breaking resistanceNo
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET IONo
Application in domestic- and commercial area permittedYes
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N12A
Supporting protocol for BACnetNo
Max. output voltage480V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV212WU55N4 | Pretvarac Frek. 5,5KW 480V 3P EMC a IP54

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital inputs

3

Height

340mm

Supporting protocol for LON

Number of analogue outputs

1

Depth

208mm

With control element

Width

230mm

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Number of analogue inputs

2

Number of HW-interfaces RS-422

0

Number of digital outputs

0

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Supporting protocol for Modbus

Mains frequency

50/60 Hz

Number of HW-interfaces parallel

0

Supporting protocol for PROFIBUS

Mains voltage

380 .. 480V

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Supporting protocol for ASI

Supporting protocol for other bus systems

Number of HW-interfaces other

0

4-quadrant operation possible

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet

With PC connection

Supporting protocol for INTERBUS

Number of interfaces PROFINET

0

With optical interface

Supporting protocol for Data-Highway

Number of HW-interfaces RS-485

1

Degree of protection (IP)

IP55

Type of converter

U converter

Number of phases output

3

Number of phases input

3

Supporting protocol for DeviceNet Safety

Application in industrial area permitted

Max. output at quadratic load at rated output voltage

5.5kW

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

5%

Max. output frequency

200Hz

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Max. output at linear load at rated output voltage

5.5kW

Supporting protocol for AS-Interface Safety at Work

Integrated breaking resistance

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET IO

Application in domestic- and commercial area permitted

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Nominal output current I2N

12A

Supporting protocol for BACnet

Max. output voltage

480V