Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supporting protocol for INTERBUSNo
Depth208mm
Number of digital outputs0
Supporting protocol for TCP/IPNo
Width230mm
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Supporting protocol for CANNo
Number of HW-interfaces USB0
Number of HW-interfaces RS-4851
Height340mm
Supporting protocol for PROFIBUSNo
Number of analogue outputs1
Number of HW-interfaces other0
Supporting protocol for ASINo
With control elementYes
Number of HW-interfaces RS-4220
With optical interfaceNo
Number of analogue inputs2
Number of HW-interfaces serial TTY0
Number of digital inputs3
Supporting protocol for LONYes
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for SERCOSNo
4-quadrant operation possibleNo
With PC connectionYes
Supporting protocol for SUCONETNo
Mains voltage380 - 480V
Mains frequency50/60 Hz
Number of phases output3
Type of converterU converter
Supporting protocol for other bus systemsYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Degree of protection (IP)IP55
Number of interfaces PROFINET0
Supporting protocol for INTERBUS-SafetyNo
Number of phases input3
Relative symmetric net voltage tolerance10%
Integrated breaking resistanceNo
Max. output at linear load at rated output voltage7.5kW
Supporting protocol for AS-Interface Safety at WorkNo
Application in industrial area permittedYes
Max. output at quadratic load at rated output voltage7.5kW
Max. output frequency200Hz
Relative symmetric net frequency tolerance5%
Application in domestic- and commercial area permittedYes
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Nominal output current I2N16A
Supporting protocol for Foundation FieldbusNo
Max. output voltage480V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for BACnetNo
Supporting protocol for DeviceNet SafetyNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV212WU75N4 | Pretvarac Frek. 7,5KW 480V 3P EMC a IP54

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supporting protocol for INTERBUS

Depth

208mm

Number of digital outputs

0

Supporting protocol for TCP/IP

Width

230mm

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces parallel

0

Supporting protocol for CAN

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Height

340mm

Supporting protocol for PROFIBUS

Number of analogue outputs

1

Number of HW-interfaces other

0

Supporting protocol for ASI

With control element

Number of HW-interfaces RS-422

0

With optical interface

Number of analogue inputs

2

Number of HW-interfaces serial TTY

0

Number of digital inputs

3

Supporting protocol for LON

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for SERCOS

4-quadrant operation possible

With PC connection

Supporting protocol for SUCONET

Mains voltage

380 .. 480V

Mains frequency

50/60 Hz

Number of phases output

3

Type of converter

U converter

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Degree of protection (IP)

IP55

Number of interfaces PROFINET

0

Supporting protocol for INTERBUS-Safety

Number of phases input

3

Relative symmetric net voltage tolerance

10%

Integrated breaking resistance

Max. output at linear load at rated output voltage

7.5kW

Supporting protocol for AS-Interface Safety at Work

Application in industrial area permitted

Max. output at quadratic load at rated output voltage

7.5kW

Max. output frequency

200Hz

Relative symmetric net frequency tolerance

5%

Application in domestic- and commercial area permitted

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Nominal output current I2N

16A

Supporting protocol for Foundation Fieldbus

Max. output voltage

480V

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Supporting protocol for BACnet

Supporting protocol for DeviceNet Safety

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.