Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital outputs0
Supporting protocol for LONNo
Number of digital inputs6
Height922mm
Width290mm
With control elementYes
Number of analogue inputs3
Depth323mm
Number of analogue outputs2
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Supporting protocol for ASINo
Number of HW-interfaces other0
With optical interfaceNo
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPYes
Supporting protocol for PROFIBUSYes
Number of HW-interfaces USB0
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetYes
Type of converterU converter
4-quadrant operation possibleYes
Mains frequency50/60 Hz
Degree of protection (IP)IP21
Supporting protocol for KNXNo
With PC connectionNo
Number of phases output3
Supporting protocol for ModbusYes
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for Data-HighwayNo
Number of interfaces PROFINET0
Mains voltage200 - 240V
Max. output at linear load at rated output voltage30kW
Number of phases input3
Supporting protocol for SafetyBUS pNo
Application in industrial area permittedYes
Supporting protocol for PROFINET IOYes
Supporting protocol for BACnetNo
Integrated breaking resistanceNo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Application in domestic- and commercial area permittedYes
Max. output at quadratic load at rated output voltage30kW
Supporting protocol for Foundation FieldbusNo
Max. output frequency500Hz
Max. output voltage240V
Supporting protocol for EtherNet/IPYes
Relative symmetric net voltage tolerance10%
Nominal output current I2N123A
Relative symmetric net frequency tolerance5%
Supporting protocol for AS-Interface Safety at WorkNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV630D30M3 | Frekventni Pret. IP21 30KW 200V/240V

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital outputs

0

Supporting protocol for LON

Number of digital inputs

6

Height

922mm

Width

290mm

With control element

Number of analogue inputs

3

Depth

323mm

Number of analogue outputs

2

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Supporting protocol for ASI

Number of HW-interfaces other

0

With optical interface

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Number of HW-interfaces USB

0

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Type of converter

U converter

4-quadrant operation possible

Mains frequency

50/60 Hz

Degree of protection (IP)

IP21

Supporting protocol for KNX

With PC connection

Number of phases output

3

Supporting protocol for Modbus

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for INTERBUS-Safety

Supporting protocol for Data-Highway

Number of interfaces PROFINET

0

Mains voltage

200 .. 240V

Max. output at linear load at rated output voltage

30kW

Number of phases input

3

Supporting protocol for SafetyBUS p

Application in industrial area permitted

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Integrated breaking resistance

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Application in domestic- and commercial area permitted

Max. output at quadratic load at rated output voltage

30kW

Supporting protocol for Foundation Fieldbus

Max. output frequency

500Hz

Max. output voltage

240V

Supporting protocol for EtherNet/IP

Relative symmetric net voltage tolerance

10%

Nominal output current I2N

123A

Relative symmetric net frequency tolerance

5%

Supporting protocol for AS-Interface Safety at Work

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.