  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of phases output3
Relative symmetric net frequency tolerance5%
Number of phases input3
Max. output at linear load at rated output voltage75kW
Number of digital outputs0
Max. output at quadratic load at rated output voltage75kW
Number of analogue inputs3
Relative symmetric net voltage tolerance10%
Application in domestic- and commercial area permittedYes
With control elementYes
Supporting protocol for SUCONETNo
Supporting protocol for TCP/IPYes
Supporting protocol for PROFIBUSYes
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for KNXNo
Supporting protocol for ASINo
Nominal output current I2N282A
Supporting protocol for INTERBUS-SafetyNo
Max. output frequency500Hz
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for LONNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces serial TTY0
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsNo
Number of analogue outputs2
Number of HW-interfaces RS-2320
Supporting protocol for CANNo
Supporting protocol for PROFINET CBANo
Application in industrial area permittedYes
Mains voltage200 - 240V
Number of HW-interfaces RS-4851
Supporting protocol for SafetyBUS pNo
Number of HW-interfaces RS-4220
Supporting protocol for DeviceNet SafetyNo
Number of HW-interfaces other0
Supporting protocol for PROFINET IOYes
Mains frequency50/60 Hz
Max. output voltage240V
Number of HW-interfaces industrial Ethernet1
Supporting protocol for PROFIsafeNo
Number of HW-interfaces parallel0
Supporting protocol for DeviceNetYes
Number of HW-interfaces USB0
Supporting protocol for Foundation FieldbusNo
Number of interfaces PROFINET0
Number of digital inputs6
Supporting protocol for BACnetNo
With optical interfaceNo
Integrated breaking resistanceNo
With PC connectionNo
4-quadrant operation possibleYes
Type of converterU converter
Width320mm
Degree of protection (IP)IP21
Height852mm
Depth390mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV630D75M3

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of phases output

3

Relative symmetric net frequency tolerance

5%

Number of phases input

3

Max. output at linear load at rated output voltage

75kW

Number of digital outputs

0

Max. output at quadratic load at rated output voltage

75kW

Number of analogue inputs

3

Relative symmetric net voltage tolerance

10%

Application in domestic- and commercial area permitted

With control element

Supporting protocol for SUCONET

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for KNX

Supporting protocol for ASI

Nominal output current I2N

282A

Supporting protocol for INTERBUS-Safety

Max. output frequency

500Hz

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Supporting protocol for LON

Supporting protocol for INTERBUS

Number of HW-interfaces serial TTY

0

Supporting protocol for SERCOS

Supporting protocol for other bus systems

Number of analogue outputs

2

Number of HW-interfaces RS-232

0

Supporting protocol for CAN

Supporting protocol for PROFINET CBA

Application in industrial area permitted

Mains voltage

200 .. 240V

Number of HW-interfaces RS-485

1

Supporting protocol for SafetyBUS p

Number of HW-interfaces RS-422

0

Supporting protocol for DeviceNet Safety

Number of HW-interfaces other

0

Supporting protocol for PROFINET IO

Mains frequency

50/60 Hz

Max. output voltage

240V

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for PROFIsafe

Number of HW-interfaces parallel

0

Supporting protocol for DeviceNet

Number of HW-interfaces USB

0

Supporting protocol for Foundation Fieldbus

Number of interfaces PROFINET

0

Number of digital inputs

6

Supporting protocol for BACnet

With optical interface

Integrated breaking resistance

With PC connection

4-quadrant operation possible

Type of converter

U converter

Width

320mm

Degree of protection (IP)

IP21

Height

852mm

Depth

390mm