Mains voltage380 - 480V
Mains frequency50/60 Hz
Number of phases input3
Max. output frequency500Hz
Number of phases output3
Max. output voltage480V
Nominal output current I2N31.7A
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage15kW
Number of digital outputs0
Max. output at quadratic load at rated output voltage15kW
Number of analogue outputs2
Number of digital inputs6
Relative symmetric net frequency tolerance5%
Number of analogue inputs3
With control elementYes
Supporting protocol for TCP/IPYes
Supporting protocol for PROFIBUSYes
Application in domestic- and commercial area permittedYes
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Application in industrial area permittedYes
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Supporting protocol for LONNo
Supporting protocol for PROFINET IOYes
Supporting protocol for DeviceNetYes
Supporting protocol for SUCONETNo
With optical interfaceNo
With PC connectionNo
Integrated breaking resistanceNo
4-quadrant operation possibleYes
Type of converterU converter
Degree of protection (IP)IP55
Height678mm
Width264mm
Depth330mm
Supporting protocol for SafetyBUS pNo
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Number of interfaces PROFINET0
Number of HW-interfaces other0
Number of HW-interfaces USB0
Supporting protocol for other bus systemsNo
Supporting protocol for PROFIsafeNo
Number of HW-interfaces RS-4851
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for AS-Interface Safety at WorkNo
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces serial TTY0
Supporting protocol for BACnetNo
Number of HW-interfaces RS-4220
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV650D15N4E

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mains voltage

380 .. 480V

Mains frequency

50/60 Hz

Number of phases input

3

Max. output frequency

500Hz

Number of phases output

3

Max. output voltage

480V

Nominal output current I2N

31.7A

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

15kW

Number of digital outputs

0

Max. output at quadratic load at rated output voltage

15kW

Number of analogue outputs

2

Number of digital inputs

6

Relative symmetric net frequency tolerance

5%

Number of analogue inputs

3

With control element

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Application in domestic- and commercial area permitted

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for KNX

Application in industrial area permitted

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

With optical interface

With PC connection

Integrated breaking resistance

4-quadrant operation possible

Type of converter

U converter

Degree of protection (IP)

IP55

Height

678mm

Width

264mm

Depth

330mm

Supporting protocol for SafetyBUS p

Number of HW-interfaces RS-232

0

Number of HW-interfaces parallel

0

Number of interfaces PROFINET

0

Number of HW-interfaces other

0

Number of HW-interfaces USB

0

Supporting protocol for other bus systems

Supporting protocol for PROFIsafe

Number of HW-interfaces RS-485

1

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for INTERBUS-Safety

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces serial TTY

0

Supporting protocol for BACnet

Number of HW-interfaces RS-422

0

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.