Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width290mm
Number of digital inputs6
Number of digital outputs0
Depth340mm
Height910mm
With control elementYes
Number of HW-interfaces RS-2320
Number of analogue outputs2
Supporting protocol for LONNo
Supporting protocol for TCP/IPYes
Number of HW-interfaces serial TTY0
Number of HW-interfaces other0
Number of HW-interfaces industrial Ethernet1
Supporting protocol for PROFIBUSYes
Number of HW-interfaces RS-4851
Supporting protocol for SUCONETNo
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
With optical interfaceNo
Supporting protocol for KNXNo
Number of HW-interfaces USB0
Supporting protocol for Data-HighwayNo
Supporting protocol for ASINo
Supporting protocol for DeviceNetYes
Supporting protocol for ModbusYes
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Number of analogue inputs3
Degree of protection (IP)IP55
With PC connectionNo
Supporting protocol for other bus systemsNo
Mains frequency50/60 Hz
Mains voltage380 - 480V
Number of interfaces PROFINET0
Number of phases output3
4-quadrant operation possibleYes
Type of converterU converter
Number of phases input3
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Max. output at quadratic load at rated output voltage37kW
Application in industrial area permittedYes
Max. output frequency500Hz
Max. output at linear load at rated output voltage37kW
Relative symmetric net frequency tolerance5%
Supporting protocol for AS-Interface Safety at WorkNo
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceNo
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IOYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
Max. output voltage480V
Nominal output current I2N72A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV650D37N4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

290mm

Number of digital inputs

6

Number of digital outputs

0

Depth

340mm

Height

910mm

With control element

Number of HW-interfaces RS-232

0

Number of analogue outputs

2

Supporting protocol for LON

Supporting protocol for TCP/IP

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

0

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-485

1

Supporting protocol for SUCONET

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

With optical interface

Supporting protocol for KNX

Number of HW-interfaces USB

0

Supporting protocol for Data-Highway

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for INTERBUS

Number of analogue inputs

3

Degree of protection (IP)

IP55

With PC connection

Supporting protocol for other bus systems

Mains frequency

50/60 Hz

Mains voltage

380 .. 480V

Number of interfaces PROFINET

0

Number of phases output

3

4-quadrant operation possible

Type of converter

U converter

Number of phases input

3

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Max. output at quadratic load at rated output voltage

37kW

Application in industrial area permitted

Max. output frequency

500Hz

Max. output at linear load at rated output voltage

37kW

Relative symmetric net frequency tolerance

5%

Supporting protocol for AS-Interface Safety at Work

Application in domestic- and commercial area permitted

Integrated breaking resistance

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Max. output voltage

480V

Nominal output current I2N

72A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.