Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width345mm
With control elementYes
Height1250mm
Number of digital outputs0
Number of analogue outputs2
Depth375mm
Number of analogue inputs3
Number of digital inputs6
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-2320
Number of HW-interfaces USB0
Number of HW-interfaces RS-4851
Number of HW-interfaces parallel0
Supporting protocol for INTERBUSNo
Number of HW-interfaces RS-4220
Number of HW-interfaces other0
Supporting protocol for TCP/IPYes
With optical interfaceNo
Number of HW-interfaces serial TTY0
Supporting protocol for ModbusYes
Degree of protection (IP)IP55
Supporting protocol for CANNo
With PC connectionNo
Supporting protocol for other bus systemsNo
Supporting protocol for KNXNo
Supporting protocol for SERCOSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for ASINo
Mains voltage380 - 480V
Supporting protocol for DeviceNetYes
Supporting protocol for PROFIBUSYes
Mains frequency50/60 Hz
Number of interfaces PROFINET0
Type of converterU converter
Number of phases output3
Max. output at linear load at rated output voltage55kW
Max. output frequency500Hz
Supporting protocol for Foundation FieldbusNo
Max. output voltage480V
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IOYes
4-quadrant operation possibleYes
Nominal output current I2N106A
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for AS-Interface Safety at WorkNo
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Relative symmetric net voltage tolerance10%
Number of phases input3
Relative symmetric net frequency tolerance5%
Max. output at quadratic load at rated output voltage55kW
Supporting protocol for DeviceNet SafetyNo
Integrated breaking resistanceNo
Supporting protocol for EtherNet/IPYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV650D55N4 | Frekventni Pret. IP55 55KW 400V/480V

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

345mm

With control element

Height

1250mm

Number of digital outputs

0

Number of analogue outputs

2

Depth

375mm

Number of analogue inputs

3

Number of digital inputs

6

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-232

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces parallel

0

Supporting protocol for INTERBUS

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

With optical interface

Number of HW-interfaces serial TTY

0

Supporting protocol for Modbus

Degree of protection (IP)

IP55

Supporting protocol for CAN

With PC connection

Supporting protocol for other bus systems

Supporting protocol for KNX

Supporting protocol for SERCOS

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Supporting protocol for ASI

Mains voltage

380 .. 480V

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

Type of converter

U converter

Number of phases output

3

Max. output at linear load at rated output voltage

55kW

Max. output frequency

500Hz

Supporting protocol for Foundation Fieldbus

Max. output voltage

480V

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

4-quadrant operation possible

Nominal output current I2N

106A

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Supporting protocol for SafetyBUS p

Supporting protocol for AS-Interface Safety at Work

Application in industrial area permitted

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Number of phases input

3

Relative symmetric net frequency tolerance

5%

Max. output at quadratic load at rated output voltage

55kW

Supporting protocol for DeviceNet Safety

Integrated breaking resistance

Supporting protocol for EtherNet/IP

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.