  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width264mm
Height678mm
Depth272mm
Number of HW-interfaces other0
With control elementYes
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Supporting protocol for CANNo
Supporting protocol for DeviceNetYes
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-4220
Number of analogue outputs2
Supporting protocol for KNXNo
With optical interfaceNo
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Supporting protocol for ModbusYes
Supporting protocol for ASINo
Number of analogue inputs3
Number of digital inputs6
Supporting protocol for PROFIBUSYes
Number of HW-interfaces serial TTY0
Number of HW-interfaces industrial Ethernet1
Number of digital outputs0
Supporting protocol for SUCONETNo
Degree of protection (IP)IP55
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsNo
Number of phases output3
Supporting protocol for SERCOSNo
Number of phases input3
With PC connectionNo
Mains frequency50/60 Hz
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Relative symmetric net voltage tolerance10%
Mains voltage380 - 480V
Relative symmetric net frequency tolerance5%
Number of interfaces PROFINET0
Max. output at linear load at rated output voltage1.5kW
Supporting protocol for EtherNet/IPYes
Supporting protocol for DeviceNet SafetyNo
Max. output frequency500Hz
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at quadratic load at rated output voltage1.5kW
Integrated breaking resistanceNo
4-quadrant operation possibleYes
Type of converterU converter
Supporting protocol for PROFINET CBANo
Nominal output current I2N4A
Supporting protocol for BACnetNo
Supporting protocol for PROFINET IOYes
Max. output voltage480V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV650U15N4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

264mm

Height

678mm

Depth

272mm

Number of HW-interfaces other

0

With control element

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-422

0

Number of analogue outputs

2

Supporting protocol for KNX

With optical interface

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Supporting protocol for Modbus

Supporting protocol for ASI

Number of analogue inputs

3

Number of digital inputs

6

Supporting protocol for PROFIBUS

Number of HW-interfaces serial TTY

0

Number of HW-interfaces industrial Ethernet

1

Number of digital outputs

0

Supporting protocol for SUCONET

Degree of protection (IP)

IP55

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

Number of phases output

3

Supporting protocol for SERCOS

Number of phases input

3

With PC connection

Mains frequency

50/60 Hz

Application in domestic- and commercial area permitted

Application in industrial area permitted

Relative symmetric net voltage tolerance

10%

Mains voltage

380 .. 480V

Relative symmetric net frequency tolerance

5%

Number of interfaces PROFINET

0

Max. output at linear load at rated output voltage

1.5kW

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Max. output frequency

500Hz

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Max. output at quadratic load at rated output voltage

1.5kW

Integrated breaking resistance

4-quadrant operation possible

Type of converter

U converter

Supporting protocol for PROFINET CBA

Nominal output current I2N

4A

Supporting protocol for BACnet

Supporting protocol for PROFINET IO

Max. output voltage

480V

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.