  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height678mm
Width264mm
Depth299mm
With control elementYes
Number of digital inputs6
Number of digital outputs0
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
With optical interfaceNo
Supporting protocol for CANNo
Number of analogue inputs3
Number of analogue outputs2
Supporting protocol for INTERBUSNo
Number of HW-interfaces other0
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-4220
Supporting protocol for ASINo
Supporting protocol for DeviceNetYes
Supporting protocol for PROFIBUSYes
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Number of HW-interfaces USB0
Supporting protocol for Data-HighwayNo
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet1
Supporting protocol for TCP/IPYes
Supporting protocol for ModbusYes
Supporting protocol for SERCOSNo
Max. output frequency500Hz
Number of phases output3
With PC connectionNo
Relative symmetric net voltage tolerance10%
Mains voltage380 - 480V
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Number of phases input3
Supporting protocol for Foundation FieldbusNo
Degree of protection (IP)IP55
Application in industrial area permittedYes
Integrated breaking resistanceNo
Supporting protocol for EtherNet/IPYes
Number of interfaces PROFINET0
Supporting protocol for DeviceNet SafetyNo
Max. output at linear load at rated output voltage7.5kW
Mains frequency50/60 Hz
Supporting protocol for other bus systemsNo
Max. output at quadratic load at rated output voltage7.5kW
Application in domestic- and commercial area permittedYes
Supporting protocol for PROFINET CBANo
Type of converterU converter
Relative symmetric net frequency tolerance5%
4-quadrant operation possibleYes
Max. output voltage480V
Nominal output current I2N16.5A
Supporting protocol for BACnetNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IOYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV650U75N4 | Frekventni Pret. IP55 7,5KW 400V/480

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height

678mm

Width

264mm

Depth

299mm

With control element

Number of digital inputs

6

Number of digital outputs

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

With optical interface

Supporting protocol for CAN

Number of analogue inputs

3

Number of analogue outputs

2

Supporting protocol for INTERBUS

Number of HW-interfaces other

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-422

0

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Supporting protocol for KNX

Number of HW-interfaces USB

0

Supporting protocol for Data-Highway

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Supporting protocol for SERCOS

Max. output frequency

500Hz

Number of phases output

3

With PC connection

Relative symmetric net voltage tolerance

10%

Mains voltage

380 .. 480V

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

Number of phases input

3

Supporting protocol for Foundation Fieldbus

Degree of protection (IP)

IP55

Application in industrial area permitted

Integrated breaking resistance

Supporting protocol for EtherNet/IP

Number of interfaces PROFINET

0

Supporting protocol for DeviceNet Safety

Max. output at linear load at rated output voltage

7.5kW

Mains frequency

50/60 Hz

Supporting protocol for other bus systems

Max. output at quadratic load at rated output voltage

7.5kW

Application in domestic- and commercial area permitted

Supporting protocol for PROFINET CBA

Type of converter

U converter

Relative symmetric net frequency tolerance

5%

4-quadrant operation possible

Max. output voltage

480V

Nominal output current I2N

16.5A

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.