Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of HW-interfaces industrial Ethernet0
Depth187mm
Number of HW-interfaces serial TTY0
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Height400mm
Number of HW-interfaces RS-4851
Width230mm
Number of HW-interfaces RS-4220
With control elementYes
Supporting protocol for CANYes
With optical interfaceNo
Supporting protocol for TCP/IPYes
Number of HW-interfaces USB0
Supporting protocol for ASINo
Number of HW-interfaces parallel0
Supporting protocol for INTERBUSYes
Supporting protocol for PROFIBUSYes
Number of HW-interfaces other0
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetYes
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Degree of protection (IP)IP20
Number of interfaces PROFINET0
Mains voltage380 - 480V
Number of phases input3
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Integrated breaking resistanceNo
4-quadrant operation possibleYes
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Max. output at linear load at rated output voltage11kW
Mains frequency50/60 Hz
Number of phases output3
With PC connectionYes
Type of converterI converter
Max. output at quadratic load at rated output voltage-kW
Max. output frequency1600Hz
Supporting protocol for EtherNet/IPYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Relative symmetric net frequency tolerance5%
Relative symmetric net voltage tolerance-%
Supporting protocol for PROFINET IONo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N27.7A
Max. output voltage480V
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV71LD27N4Z

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of HW-interfaces industrial Ethernet

0

Depth

187mm

Number of HW-interfaces serial TTY

0

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Height

400mm

Number of HW-interfaces RS-485

1

Width

230mm

Number of HW-interfaces RS-422

0

With control element

Supporting protocol for CAN

With optical interface

Supporting protocol for TCP/IP

Number of HW-interfaces USB

0

Supporting protocol for ASI

Number of HW-interfaces parallel

0

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Number of HW-interfaces other

0

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for KNX

Degree of protection (IP)

IP20

Number of interfaces PROFINET

0

Mains voltage

380 .. 480V

Number of phases input

3

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Integrated breaking resistance

4-quadrant operation possible

Application in domestic- and commercial area permitted

Application in industrial area permitted

Max. output at linear load at rated output voltage

11kW

Mains frequency

50/60 Hz

Number of phases output

3

With PC connection

Type of converter

I converter

Max. output at quadratic load at rated output voltage

-kW

Max. output frequency

1600Hz

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Relative symmetric net frequency tolerance

5%

Relative symmetric net voltage tolerance

-%

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

27.7A

Max. output voltage

480V

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.