Technical specifications

Width35mm
ModelModular
Number of HW-interfaces industrial Ethernet2
Suitable for safety functionsYes
Depth160mm
Number of analogue inputs128
Height100mm
With displayNo
Number of digital inputs512
Supporting protocol for LONNo
Processing time (1K, binary operation)18ms
Memory size2048kByte
Number of digital outputs512
Type of memoryNVRAM
Number of analogue outputs128
Voltage type of supply voltageDC
Supporting protocol for KNXNo
Number of HW-interfaces RS-4220
Number of HW-interfaces other2
Number of HW-interfaces USB1
Additional program memory possibleYes
Supporting protocol for CANNo
Supporting protocol for ModbusYes
With optical interfaceNo
Supporting protocol for ASIYes
Supporting protocol for INTERBUSNo
Number of HW-interfaces RS-4851
Supporting protocol for PROFIBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPYes
RedundancyNo
Supporting protocol for other bus systemsNo
Rail mounting possibleYes
Explosion safety category for gasNone
Number of HW-interfaces RS-2321
Explosion safety category for dustNone
Appendant operation agent (Ex ia)No
System accessoryNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
Rack-assembly possibleYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Performance level according to EN ISO 13849-1None
Supporting protocol for PROFINET IONo
Number of HW-interfaces Wireless0
Front built-in possibleYes
Supporting protocol for EtherNet/IPYes
Radio standard BluetoothNo
Supporting protocol for DeviceNet SafetyNo
Appendant operation agent (Ex ib)No
Supply voltage AC 60 Hz0 - 0V
Max. number of time switches0
Supporting protocol for PROFINET CBANo
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for Foundation FieldbusNo
Radio standard Wi-Fi 802.11No
Wall mounting/direct mountingYes
IO link masterNo
Supporting protocol for SafetyBUS pNo
Number of relay outputs0
Supply voltage DC24 - 24V
Radio standard GSMNo
Radio standard UMTSNo
Radio standard GPRSNo
Supporting protocol for DNP3No
Supporting protocol for IEC 61850 EthernetNo
Supporting protocol for IEC 60870No
Long-Term Evolution (LTE)No
SIL according to IEC 61508None
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BMXP341000

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

35mm

Model

Modular

Number of HW-interfaces industrial Ethernet

2

Suitable for safety functions

Depth

160mm

Number of analogue inputs

128

Height

100mm

With display

Number of digital inputs

512

Supporting protocol for LON

Processing time (1K, binary operation)

18ms

Memory size

2048kByte

Number of digital outputs

512

Type of memory

NVRAM

Number of analogue outputs

128

Voltage type of supply voltage

DC

Supporting protocol for KNX

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

2

Number of HW-interfaces USB

1

Additional program memory possible

Supporting protocol for CAN

Supporting protocol for Modbus

With optical interface

Supporting protocol for ASI

Supporting protocol for INTERBUS

Number of HW-interfaces RS-485

1

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Redundancy

Supporting protocol for other bus systems

Rail mounting possible

Explosion safety category for gas

None

Number of HW-interfaces RS-232

1

Explosion safety category for dust

None

Appendant operation agent (Ex ia)

System accessory

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Number of interfaces PROFINET

0

Rack-assembly possible

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Performance level according to EN ISO 13849-1

None

Supporting protocol for PROFINET IO

Number of HW-interfaces Wireless

0

Front built-in possible

Supporting protocol for EtherNet/IP

Radio standard Bluetooth

Supporting protocol for DeviceNet Safety

Appendant operation agent (Ex ib)

Supply voltage AC 60 Hz

0 .. 0V

Max. number of time switches

0

Supporting protocol for PROFINET CBA

Supply voltage AC 50 Hz

0 .. 0V

Supporting protocol for Foundation Fieldbus

Radio standard Wi-Fi 802.11

Wall mounting/direct mounting

IO link master

Supporting protocol for SafetyBUS p

Number of relay outputs

0

Supply voltage DC

24 .. 24V

Radio standard GSM

Radio standard UMTS

Radio standard GPRS

Supporting protocol for DNP3

Supporting protocol for IEC 61850 Ethernet

Supporting protocol for IEC 60870

Long-Term Evolution (LTE)

SIL according to IEC 61508

None

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.