Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
0 - 0V
Supply voltage AC 60 Hz
0 - 0V
Supply voltage DC
24 - 24V
Number of relay outputs
0
Voltage type of supply voltage
DC
Number of HW-interfaces RS-232
1
Number of HW-interfaces other
4
Model
Modular
Number of digital inputs
1024
Number of HW-interfaces RS-485
1
With optical interface
No
Supporting protocol for CAN
Yes
Number of digital outputs
1024
Number of HW-interfaces industrial Ethernet
2
Supporting protocol for TCP/IP
Yes
Number of interfaces PROFINET
0
Number of analogue outputs
256
Processing time (1K, binary operation)
12ms
Radio standard UMTS
No
Number of HW-interfaces parallel
0
Max. number of time switches
0
Supporting protocol for PROFIBUS
No
Number of HW-interfaces RS-422
0
Supporting protocol for EtherCAT
No
Supporting protocol for INTERBUS
No
Number of HW-interfaces USB
1
Number of analogue inputs
256
Number of HW-interfaces Wireless
0
Radio standard 4G
No
IO link master
No
System accessory
No
Redundancy
No
With display
No
Type of memory
NVRAM
Memory size
4096kByte
Additional program memory possible
Yes
Rail mounting possible
Yes
Wall mounting/direct mounting
Yes
Rack-assembly possible
Yes
Front built-in possible
Yes
Suitable for safety functions
Yes
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for dust
None
Certified for UL hazardous location class I
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Explosion safety category for gas
None
Certified for UL hazardous location class III
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Certified for UL hazardous location group G (non-conductive dusts)
No
Width
35mm
Height
100mm
Depth
160mm
Supporting protocol for ASI
Yes
Supporting protocol for KNX
No
Supporting protocol for Modbus
Yes
Supporting protocol for DeviceNet
No
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DNP3
No
Supporting protocol for other bus systems
No
Supporting protocol for PROFIsafe
No
Supporting protocol for IEC 60870
No
Radio standard Bluetooth
No
Radio standard GPRS
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for IEC 61850 Ethernet
No
Radio standard Wi-Fi 802.11
No
Radio standard GSM
No
BMXP3420302

Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
0 .. 0V
Supply voltage AC 60 Hz
0 .. 0V
Supply voltage DC
24 .. 24V
Number of relay outputs
0
Voltage type of supply voltage
DC
Number of HW-interfaces RS-232
1
Number of HW-interfaces other
4
Model
Modular
Number of digital inputs
1024
Number of HW-interfaces RS-485
1
With optical interface
Supporting protocol for CAN
Number of digital outputs
1024
Number of HW-interfaces industrial Ethernet
2
Supporting protocol for TCP/IP
Number of interfaces PROFINET
0
Number of analogue outputs
256
Processing time (1K, binary operation)
12ms
Radio standard UMTS
Number of HW-interfaces parallel
0
Max. number of time switches
0
Supporting protocol for PROFIBUS
Number of HW-interfaces RS-422
0
Supporting protocol for EtherCAT
Supporting protocol for INTERBUS
Number of HW-interfaces USB
1
Number of analogue inputs
256
Number of HW-interfaces Wireless
0
Radio standard 4G
IO link master
System accessory
Redundancy
With display
Type of memory
NVRAM
Memory size
4096kByte
Additional program memory possible
Rail mounting possible
Wall mounting/direct mounting
Rack-assembly possible
Front built-in possible
Suitable for safety functions
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Explosion safety category for dust
None
Certified for UL hazardous location class I
Certified for UL hazardous location class II
Certified for UL hazardous location division 1
Certified for UL hazardous location division 2
Explosion safety category for gas
None
Certified for UL hazardous location class III
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Width
35mm
Height
100mm
Depth
160mm
Supporting protocol for ASI
Supporting protocol for KNX
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for PROFINET CBA
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DNP3
Supporting protocol for other bus systems
Supporting protocol for PROFIsafe
Supporting protocol for IEC 60870
Radio standard Bluetooth
Radio standard GPRS
Supporting protocol for SafetyBUS p
Supporting protocol for IEC 61850 Ethernet
Radio standard Wi-Fi 802.11
Radio standard GSM