Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP20
Number of poles3
Type of control elementToggle
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu100A
Number of auxiliary contacts as normally open contact0
Motor drive optionalNo
Overload release current setting0 - 0A
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Rated voltage550 - 550V
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release0 - 0A
Integrated earth fault protectionNo
With switched-off indicatorYes
Adjustment range short-term delayed short-circuit release0 - 0A
Position of connection for main current circuitFront connection
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
With under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

EZC100N3050

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP20

Number of poles

3

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

100A

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Overload release current setting

0 .. 0A

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Rated voltage

550 .. 550V

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

0 .. 0A

Integrated earth fault protection

With switched-off indicator

Adjustment range short-term delayed short-circuit release

0 .. 0A

Position of connection for main current circuit

Front connection

DIN rail (top hat rail) mounting optional

Complete device with protection unit

With under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

15kA

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.