Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Rated voltage250V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V1.5kA
Voltage typeAC
Current limiting class3
Over voltage category3
Flush-mounted installationNo
Rated insulation voltage Ui250V
Additional equipment possibleNo
Width in number of modular spacings1
Rated current10A
Built-in depth74mm
Number of poles (total)1
Pollution degree2
Release characteristicOther
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Number of protected poles1
Ambient temperature during operating-20 - 60°C
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 4mm²
Connectable conductor cross section solid-core0.75 - 6mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GB2CB16

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated voltage

250V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

1.5kA

Voltage type

AC

Current limiting class

3

Over voltage category

3

Flush-mounted installation

Rated insulation voltage Ui

250V

Additional equipment possible

Width in number of modular spacings

1

Rated current

10A

Built-in depth

74mm

Number of poles (total)

1

Pollution degree

2

Release characteristic

Other

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Number of protected poles

1

Ambient temperature during operating

-20 .. 60°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 4mm²

Connectable conductor cross section solid-core

0.75 .. 6mm²

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.