Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)2
Flush-mounted installationNo
Voltage typeAC
Rated insulation voltage Ui250V
Number of protected poles1
Pollution degree2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Current limiting class3
Release characteristicOther
Built-in depth74mm
Rated current2A
Rated voltage250V
Over voltage category3
Additional equipment possibleNo
Frequency50 - 60Hz
Width in number of modular spacings1
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 4mm²
Connectable conductor cross section solid-core0.75 - 6mm²
Ambient temperature during operating-20 - 60°C
Explosion-proofNo
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GB2CD07

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

2

Flush-mounted installation

Voltage type

AC

Rated insulation voltage Ui

250V

Number of protected poles

1

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Current limiting class

3

Release characteristic

Other

Built-in depth

74mm

Rated current

2A

Rated voltage

250V

Over voltage category

3

Additional equipment possible

Frequency

50 .. 60Hz

Width in number of modular spacings

1

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 4mm²

Connectable conductor cross section solid-core

0.75 .. 6mm²

Ambient temperature during operating

-20 .. 60°C

Explosion-proof

Rated impulse withstand voltage Uimp

4kV

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.