Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Connectable conductor cross section solid-core0.75 - 6mm²
Degree of protection (IP)IP20
Number of protected poles1
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V2kA
Rated insulation voltage Ui250V
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Concurrently switching neutral conductorYes
Additional equipment possibleNo
Rated voltage250V
Width in number of modular spacings1
Current limiting class3
Ambient temperature during operating-20 - 60°C
Pollution degree2
Built-in depth74mm
Connectable conductor cross section multi-wired0.75 - 4mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Flush-mounted installationNo
Frequency50 - 60Hz
Voltage typeAC
Rated impulse withstand voltage Uimp4kV
Rated current5A
Release characteristicOther
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GB2CD10 | Min. Prekidac TeSys_GB2 1PN 5A Id=66A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Connectable conductor cross section solid-core

0.75 .. 6mm²

Degree of protection (IP)

IP20

Number of protected poles

1

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

2kA

Rated insulation voltage Ui

250V

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Concurrently switching neutral conductor

Additional equipment possible

Rated voltage

250V

Width in number of modular spacings

1

Current limiting class

3

Ambient temperature during operating

-20 .. 60°C

Pollution degree

2

Built-in depth

74mm

Connectable conductor cross section multi-wired

0.75 .. 4mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Flush-mounted installation

Frequency

50 .. 60Hz

Voltage type

AC

Rated impulse withstand voltage Uimp

4kV

Rated current

5A

Release characteristic

Other

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA