Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)2
Release characteristicOther
Rated current12A
Rated voltage250V
Voltage typeAC
Current limiting class3
Rated insulation voltage Ui250V
Concurrently switching neutral conductorYes
Built-in depth74mm
Over voltage category3
Frequency50 - 60Hz
Number of protected poles1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V1.5kA
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 4mm²
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleNo
Pollution degree2
Explosion-proofNo
Ambient temperature during operating-20 - 60°C
Degree of protection (IP)IP20
Width in number of modular spacings1
Connectable conductor cross section solid-core0.75 - 6mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GB2CD20

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

2

Release characteristic

Other

Rated current

12A

Rated voltage

250V

Voltage type

AC

Current limiting class

3

Rated insulation voltage Ui

250V

Concurrently switching neutral conductor

Built-in depth

74mm

Over voltage category

3

Frequency

50 .. 60Hz

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

1.5kA

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 4mm²

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Pollution degree

2

Explosion-proof

Ambient temperature during operating

-20 .. 60°C

Degree of protection (IP)

IP20

Width in number of modular spacings

1

Connectable conductor cross section solid-core

0.75 .. 6mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.