Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)2
Number of protected poles2
Release characteristicOther
Built-in depth78mm
Rated voltage415V
Rated current0.5A
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui415V
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Over voltage category3
Flush-mounted installationNo
Pollution degree2
Concurrently switching neutral conductorNo
Additional equipment possibleNo
Width in number of modular spacings2
Degree of protection (IP)IP20
Ambient temperature during operating-20 - 60°C
Connectable conductor cross section solid-core0.75 - 6mm²
Connectable conductor cross section multi-wired0.75 - 4mm²
Explosion-proofNo
Current limiting class3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GB2DB05

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

2

Number of protected poles

2

Release characteristic

Other

Built-in depth

78mm

Rated voltage

415V

Rated current

0.5A

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

415V

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Over voltage category

3

Flush-mounted installation

Pollution degree

2

Concurrently switching neutral conductor

Additional equipment possible

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Ambient temperature during operating

-20 .. 60°C

Connectable conductor cross section solid-core

0.75 .. 6mm²

Connectable conductor cross section multi-wired

0.75 .. 4mm²

Explosion-proof

Current limiting class

3

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.