Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated voltage415V
Rated impulse withstand voltage Uimp4kV
Release characteristicOther
Frequency50 - 60Hz
Number of protected poles2
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V2kA
Concurrently switching neutral conductorNo
Voltage typeAC
Rated insulation voltage Ui415V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V2kA
Current limiting class3
Width in number of modular spacings2
Rated current5A
Connectable conductor cross section solid-core0.75 - 6mm²
Degree of protection (IP)IP20
Built-in depth78mm
Pollution degree2
Additional equipment possibleNo
Explosion-proofNo
Ambient temperature during operating-20 - 60°C
Connectable conductor cross section multi-wired0.75 - 4mm²
Number of poles (total)2
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GB2DB10

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated voltage

415V

Rated impulse withstand voltage Uimp

4kV

Release characteristic

Other

Frequency

50 .. 60Hz

Number of protected poles

2

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

2kA

Concurrently switching neutral conductor

Voltage type

AC

Rated insulation voltage Ui

415V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

2kA

Current limiting class

3

Width in number of modular spacings

2

Rated current

5A

Connectable conductor cross section solid-core

0.75 .. 6mm²

Degree of protection (IP)

IP20

Built-in depth

78mm

Pollution degree

2

Additional equipment possible

Explosion-proof

Ambient temperature during operating

-20 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 4mm²

Number of poles (total)

2

Over voltage category

3

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.