Technical specifications

Built-in depth78mm
Frequency50 - 60Hz
Rated current5A
Rated voltage415V
Voltage typeAC
Rated insulation voltage Ui415V
Width in number of modular spacings2
Pollution degree2
Over voltage category3
Current limiting class3
Connectable conductor cross section multi-wired0.75 - 4mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Concurrently switching neutral conductorNo
Number of protected poles2
Release characteristicOther
Additional equipment possibleNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section solid-core0.75 - 6mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V2kA
Flush-mounted installationNo
Ambient temperature during operating-20 - 60°C
Number of poles (total)2
Explosion-proofNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V2kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GB2DB10 | Min. Prekidac TeSys_GB2 2P 5A Id=66A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

78mm

Frequency

50 .. 60Hz

Rated current

5A

Rated voltage

415V

Voltage type

AC

Rated insulation voltage Ui

415V

Width in number of modular spacings

2

Pollution degree

2

Over voltage category

3

Current limiting class

3

Connectable conductor cross section multi-wired

0.75 .. 4mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Concurrently switching neutral conductor

Number of protected poles

2

Release characteristic

Other

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section solid-core

0.75 .. 6mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

2kA

Flush-mounted installation

Ambient temperature during operating

-20 .. 60°C

Number of poles (total)

2

Explosion-proof

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

2kA

Rated impulse withstand voltage Uimp

4kV