Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage typeAC
Rated insulation voltage Ui415V
Built-in depth78mm
Rated voltage415V
Rated current6A
Current limiting class3
Frequency50 - 60Hz
Pollution degree2
Release characteristicOther
Over voltage category3
Width in number of modular spacings2
Degree of protection (IP)IP20
Explosion-proofNo
Ambient temperature during operating-20 - 60°C
Connectable conductor cross section multi-wired0.75 - 4mm²
Additional equipment possibleNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V1.5kA
Number of protected poles2
Connectable conductor cross section solid-core0.75 - 6mm²
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V1.5kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GB2DB12 | Min. Prekidac TeSys_GB2 2P 6A Id=83A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Voltage type

AC

Rated insulation voltage Ui

415V

Built-in depth

78mm

Rated voltage

415V

Rated current

6A

Current limiting class

3

Frequency

50 .. 60Hz

Pollution degree

2

Release characteristic

Other

Over voltage category

3

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Explosion-proof

Ambient temperature during operating

-20 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 4mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

1.5kA

Number of protected poles

2

Connectable conductor cross section solid-core

0.75 .. 6mm²

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

1.5kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.